Central con pantalla de 24 vdc para cancela corredera
Ocultar thumbs Ver también para ELVOX RS06:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
N.B.:
After calibrating the travel, if parameters 11-12-13-14 and 31 are changed after confirming with the ENTER key the display reads APCH, you must give
the command by pressing the APCH button, the gate will perform a complete opening and closing cycle (with this operation, the control unit saves the new
current thresholds with the modified speeds)
7.5 DEF:
used to set the control panel on the default parameters except for parameters 9-10-11-12-14-15-22-23-24-26-31, press and release the OK button,
the display shows 4 dots to confirm the operation.
7.6 CNT:
used to view the number of openings followed by the gearmotor, the first counter A displays the number of absolute operations, the second counter
P displays the operations performed after a reset controlled by the installer. This is shown in the following example:
x5
Pressing the UP button 6 times displays CNT (counter)
Press the OK button, the display shows the letter A (absolute counter cannot be reset) the number that follows should be multiplied by 10000
Press the DOWN button, the display shows the number to be added to get the total openings performed by the motor: absolute number =
(000*10000)+(7000)= 7000
Press the DOWN button, the display shows the letter P (partial counter can be reset) the number that follows should be multiplied by 1000
Press the DOWN button, the display shows the number to be added to get the openings after resetting the partial counter: partial
number = (000*10000)+(1000)= 1000, this means that it was reset on 6000 openings. To reset the partial counter, press
and hold down the OK button for at least 5 seconds.
7.7 ERR:
Shows the last 9 faults or errors: when the gate is not moving, you can view the last fault during operation.
Pressing the UP button 7 times displays Err (list of faults or errors)
Press the OK button, the display shows the letter 1.F Xx , the first digit indicates the progressive error log number, ranging from 1 to 9, the highest value
indicates the most recent error, xx indicates the type of error, see the errors table:
To clear the error list: enter the ERR menu and hold down the OK button for at least 5 seconds.