7.3

Technician Menu

Menu #
Name
51
Cl P factor
52
Cl pump period
53
Cl pump freq
54
Cl Overfeed Time
55
Cl Averaging
56
Cl < 0.1 Alarm
57
pH p factor
58
pH pump period
59
pH pump freq
pH Overfeed
60
Time
61
pH balance type
62
Flow Sensor
63
Flow Rate
64
Celsius/Farh
65
Temp Hysteresis
66
Turbidity
NTU wiper
67
interval
68
Minutes
69
Hour
70
Day
71
Month
72
Year
73
Recording Interval
74
Address
75
Software Version
Operator
76
Password
Technical
77
Password
Proportional Factor for Cl Relay 1
1 Pump cycle (on +off time) for Cl Relay 1
Cl pump max pulses/min, 0 for on/off pump
Will open relay 1+2 if Cl feeding continuously for this time
Displays an average of the last 4 Cl readings
If Cl drops below this level, Alarm indicated and Opens Cl Relay 1+2
Proportional Factor for pH Relay 3
1 Pump cycle (on +off time) for pH Relay 3
pH pump max pulses/min, 0 for on/off pump
Will open relay 3 if pH feeding continuously for this time
To Select if Acid of Base is being added to adjust pH
Will turn display of Flow rate on/off (only use if flow meter
Choose between metric and US units
Choose between metric and US units
Value in degrees, below set-point which will close Temp Relay 6
Turns Turbidity Module ON/OFF (optional module)
Interval for Turbidity Module Wiper to clean glass (optional module)
Current Time for Data Logger
Current Time for Data Logger
Current Time for Data Logger
Current Time for Data Logger
Current Time for Data Logger
Time interval between readings stored on the on-board data logger
Controller ID - used with external communication
Current software version
Change operator password
Change technician password
70
Description
connected)

Capítulos