Calibration and Initial Operation Checklist

Before leaving the site, perform the procedure in this section and record the requested values.
1. Calibrate the following HydroGuard parameters and enter the information into the table below. If pH and
ORP are reading slightly low, do not calibrate as they will continue to increase for the first 24-48 hours.
Date
Parameter
Chlorine
pH
Redox (ORP)
Temperature
Perform the following tests:
2. Press the pH Mode button on the control panel to change the mode to On.
Check that the dosing system is adding acid or base chemicals to the pool water.
3. Press the pH Mode button on the control panel to return the pH mode to Auto.
4. Press the Cl Mode button on the control panel to change mode to On.
Check that the dosing system is adding chlorine to pool water.
5. Press the Cl Mode button on control panel to return chlorine mode to Auto.
6. Turn off the main circulation pump.
Check that the dosing systems are not adding any chemicals to the pool water.
Site
Controller Reading
Technician's Name
External Device or Standard Value
34