ENGLISH
DESCRIPTION
Mynute Green 25 R.S.I. E
Burner: number of nozzles - diameter of nozzles - lenght
Diaphragm: number of holes - diameter of holes
Heating maximum gas capacity
Heating minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions (CH)
Minimum number of fan revolutions (CH)
Mynute Green 35 R.S.I. E
Burner: number of nozzles - diameter of nozzles - lenght
Diaphragm: number of holes - diameter of holes
Heating maximum gas capacity
Heating minimum gas capacity
Numbers of fan revolutions at slow start
Maximum number of fan revolutions (CH)
Minimum number of fan revolutions (CH)
22
Methane gas (G20)
n° - mm - mm
1 - 63 - 130
n° - mm
1 - 6,7
Sm
/h
2,64
3
kg/h
Sm
/h
0,63
3
kg/h
revs/min
3.400
revs/min
5.600
revs/min
1.700
n° - mm - mm
1 - 63 - 140
n° - mm
1 - 7
Sm
/h
3,66
3
kg/h
Sm
/h
0,74
3
kg/h
revs/min
3.700
revs/min
5.900
revs/min
1.400
Propane (G31)
1 - 63 - 130
1 - 4,7
1,94
0,47
3.400
5.600
1.700
1 - 63 - 140
1 - 5
2,69
0,54
3.700
5.900
1.400