1. Determine whether hood will discharge vertically (3¼" x 10"
or 7" Round) or horizontally (3¼" x 10" only).
2. Run ductwork between the hood location and a roof cap
or wall cap.
3. The ducting from this fan to the outside of the building has
a strong eff ect on the air fl ow, noise and energy use of
the fan. Use the shortest, straightest duct routing possible
for best performance, and avoid installing the fan with
smaller ducts than recommended. Insulation around the
ducts can reduce energy loss and inhibit mold growth.
Fans installed with existing ducts may not achieve their
rated airfl ow. Refer to the table below to help you plan
the most effi cient installation.
4. Install wall cap or roof cap (sold separately); ensure there
is no leak in hoiouse insulation. Connect metal ductwork
to cap and work back towards the hood location. Use 2"
metal foil duct tape to seal the joints between ductwork
sections.
Maximum Duct Lengths Recommended to Achieve 80% Exhaust Effi ciency
3¼"
10" H
X
ORIZONTAL
M
D
AXIMUM
UCT LENGTH
91 ft.
82 ft.
73 ft.
* Standard elbows with 1" internal radius.
1. If present, remove all protective polyfi lm from the hood
and/or parts. Using the fi nger cup, remove the Micromesh
Filters from the hood by pushing down and tilting fi lters
out.
2. Remove the EZ1 brackets from inside the hood by
cutting off the tie wrap. Remove both screws holding
damper assembly to hood. Remove parts bag (captured
behind the damper assembly). Remove damper assembly
from inside the hood and keep the screws for further use.
INSTALL DUCTWORK (DUCTED INSTALLATION ONLY)
3¼"
10" V
X
ERTICAL
M
D
AXIMUM
UCT LENGTH
79 ft.
71 ft.
62 ft.
PREPARE THE HOOD
R
OOF CAP
S
OFFIT
C
ABINET
H
18"
- 24"
MIN
MAX
ABOVE COOKING SURFACE
NOTE: Distances over 24" are at the installer and user
discretion.
7" R
M
R
OUND
AXIMUM
OOF OR
D
UCT LENGTH
CAP WITH
92 ft.
78 ft.
62 ft.
EZ1
BRACKETS
7
3¼"
10"
X
OR
7"
ROUND DUCT
(F
OR VERTICAL
)
DISCHARGE
H
OUSE WIRING
(T
OP OR BACK OF HOOD
W
ALL CAP
OOD
3¼"
10"
X
(F
OR HORIZONTAL DISCHARGE
W
E
(
ALL
LBOW
D
(90°
/
AMPER
AND
OR
1
0
1
1
1
2
B
C
)
DUCT
)
)*
S
45°)
SCREWS
DAMPER
ASSEMBLY