INDICATOR LAMP
BLUE (ref. 1g, FIG.10)
Electric power supply correct, phase sequence correct
RED (ref.1h, FIG.10)
Thermal magnetic cut-out of mortar pump (ref.), cell wheel (ref.) or
compressor/water pump (ref.) tripped
GREEN (ref.1i, FIG.10)
No water pressure
WHITE (ref.1c, FIG.10)
Start button pressed: machine operates correctly
IMER INTERNATIONAL S.p.A.
KOINE 4/5
INDICATOR LAMP TABLE
ON
27
OFF
- No electric power supply
- Phase missing
- Phase sequence error
- Main switch set to 0
- Thermal magnetic cut-outs tripped
- Water pressure correct
- Stop button pressed: machine stationary
- Start button pressed: machine stationary:
1. Mixing chamber is open and the safety sensor has tripped.
2. The mixing chamber is closed and the safety thermocouple of the mortar pump
motor has tripped