7. SYSTEM OPERATION.
7.1. DESCRIPTION OF THE SCREENS.
When the inverter is started, the following interfaces will be
displayed on the OLED screen, which allows the user to check
different types of operating information, as well as to change the
inverter settings. Please refer to the following screen operation
flow chart for more details:
"Status" screen menu.
1.
Screen 0.1
Inverter status indicator and the power it is gen-
erating.
"Waiting" status: The inverter is receiving power from the
ˆ
panels, but it does not detect a connection to the grid.
"Verifying" status: The inverter has panel and is receiving
ˆ
power from the grid, and is performing internal checks be-
fore start-up.
"Normal" status: Under production and without anomalies.
ˆ
"Failure" status: Without production and with anomalies.
ˆ
"PV1" Screen menu.
2.
Screen 1.1
Indicator of the voltage and intensity of the solar
field connected to the MPPT 1.
"PV2" Screen menu.
3.
Screen 2.1
Indicator of the voltage and intensity of the solar
field connected to the MPPT 2 (Only for EQX2 3002-S, EQX2
3002-SX, EQX2 4002-S, EQX2 4002-SX, EQX 5002-S, EQX2
5002-SX, EQX2 6002-S, EQX2 6002-SX, EQX2 8002-SX and
EQX2 10002-SX units).
"V grid" screen menu.
4.
Screen 3.1
Indicator of the grid voltage.
"I grid" screen menu.
5.
Screen 4.1
Indicator of the intensity supplied to the installa-
tion.
"F grid" screen menu.
6.
Screen 5.1
Indicator of the grid frequency.
"E. Day" screen menu.
7.
Screen 6.1
Indicator of the energy generated during the day.
"E. Total" screen menu.
8.
Screen 7.1
Indicator of the energy that has been generated
since the start-up of the inverter.
"Time ON" screen menu.
9.
Screen 8.1
Indicator of the time that the inverter has been in
operation since its start-up.
"Unit Model" screen menu.
10.
Screen 9.1
Unit code indicator.
"General Settings" screen menu.
11.
Screen 10.1
Main screen of the "General Settings" menu.
Screen 10.2
"Info.System" Inverter information.
Screen 10.2.1 Firmware version of the device.
Continued 10.2.3.
62
Screen 10.2.2 SSID. Wi-Fi identification.
Screen 10.2.3 FW version (II).
Screen 10.2.4 Verification code for pairing the connection
with the Dongle.
Screen 10.3
Fault Info.
Screen 10.4
RSSI. Indicator of the intensity of the WiFi signal
received (Received Signal Strength Indicator).
Screen 10.5
Rest. WiFi. Reset the Wi-Fi settings.
Screen 10.6
WiFi RELD. Update the unit via WiFi.
Screen 10.7
Safety UNE 217002.
Screen 10.7.1 EN50549.
Screen 10.7.2 Vietnam.
Screen 10.7.3 IEC (50 Hz).
Screen 10.7.4 IEC (60 Hz).
Screen 10.7.5 India.
Screen 10.7.6 Philippines.
Screen 10.7.7 Sri Lanka.
Screen 10.7.8 EN50549(Cz).
Screen 10.7.9 EN50549(Tr).
Screen 10.7.10 EN50549(Ie).
Screen 10.7.11 EN50549(Se).
Screen 10.7.12 EN50549(Pl).
Screen 10.7.13 EN50549(Hr).
Screen 10.7.14 Belgium.
Screen 10.7.15 Fra mainland.
Screen 10.7.16 France (50 Hz).
Screen 10.7.17 France (60 Hz).
Screen 10.7.18 VDE0126.
Screen 10.7.19 50 Hz default.
Screen 10.7.20 60 Hz default.
Screen 10.7.21 VDE4105.
Screen 10.8 P.
Limit
ON/OFF.
power.
Screen 10.9
Export/ Rated P. Percentage injected into the
grid. 0% for zero injection and 100% to dump surpluses into
the grid.
Screen 10.10
Power factor.
Screen 10.11
CT ratio. Transformation ratio of the current
transformer (CT).
Screen 10.12
Reconnection.
Screen 10.13
Modbus Addr.
Screen 10.14
Date/Time.
Screen 10.14.1 yyyy-mm-dd and hh:mm:ss.
Screen 10.15
Language.
Screen 10.15.0 Spanish Language.
Screen 10.15.1 Portuguese language.
Screen 10.15.2 Polish language.
Screen 10.15.3 English Language.
Function to limit the inverter
SALICRU
loading