Kenmore 263.1470 Serie Manual De Uso Y Cuidado página 30

Idiomas disponibles

Idiomas disponibles

AUTOMATIC FAULT WARNINGS AND WHAT TO DO
TROUBLE CODE
FF
F5
F3
F2
F8
F1
F7
F9
F6
HI
POSSIBLE FAULT
Water inlet system failure
Pressure system failure
Continuous water input
Inability to discharge water
Heater error
Overflow
Overheating
Divisor position error
Faulty heater sensor
High voltage failure
USA - CAN - 29
WHAT TO DO
Make sure the water inlet tap is
open and water is flowing.
Separate the inlet hose from the
tap and clean the filter of the
hose.
Contact for service if the error
continues.
Contact for service.
Close the tap and contact for
service.
Water discharge hose and filters
may be clogged.
Cancel the cycle.
If the error continues, contact for
service.
Contact for service.
Unplug the machine and close
the tap.
Contact for service.
Contact for service.
Contact for service.
Contact for service.
Contact for service.
loading