ALARM 6:
Cause: Fume probe problem mismatch or bad contact.
Solution: 1. Check that the smoke probe is connected.
2. Change the smoke probe.
ALARM 7:
Cause: Pressure switch or flue problem with insufficient draft.
Solution: 1. Recheck or replace the pressure switch.
2. Recheck or replace the exhaust fan.
3. Check the sealing of the door.
4. Check and clean the flue, check the Draught.
ALARM 8:
Cause: Temperature sensor problem or bad contact.
Solution: 1. Check the room temperature sensor.
2. Replace it.