3.4 Setting the temperature
Setting the room temperature
Power on, press the button
, set the temperature as you wish, press
or
to increase or
decrease the temperature, press the button
to exit.
Set the firepower level
Press
to enter the firepower mode, 5 levels of firepower, ranging from 1 to 5, the 1st level being the
weakest and the 5th the strongest. 1 displayed image corresponds to the 1st level, 2nd displayed image
corresponds to the 2nd level, etc. Press
or
to set, then press
to confirm and exit.
The settings have been configured at the factory and normally do not require any adjustment. In case of
adjustment due to the difference in calorific value of the pellets, avoid overloading the pellets, which would
cause too much fire, waste the pellets and reduce the life of the stoves. Here's how to check if the fire is too
strong: during normal operation, press
to check the flue gas temperature (Flue T), it must be less than the
factory's nominal value, ≦200°C. If the exhaust temperature is too high, it means that the fire is too strong,
reduce the amount of pellets according to the power requested.