GB
Run capacitor replacement for VLS504A AC
The run capasitor is placed in the left side
of the compressor compartment, fixed to
the compressor bracket.
2. Pull out the cover to remove
4. Use a nose plier to unmount the wire
sockets.
1. Dismount the cover by pushing the cover
lock from right to the left with a flat screw
driver.
3. Flip out the clamp to free the capasitor
from the bracket.
5. Loosen the screw for cord relieve and
pulle out the wire. The capasitor kan be
remounted in reverse ordrer.
36