Kübler Group
What the measuring system does not fulfill
The following is not provided by the measuring system; this must be ensured by external
devices:
• The measured position is not evaluated. This requires a safe evaluation unit or controller that
will be able to fulfill various position-dependent safety functions.
• In case of error the measuring system does not transmit position data, just error codes. For
this reason, the transmission of a position within a specific time is not guaranteed. Missing
position data has to be detected and evaluated by an external evaluation unit.
• The measuring system in no way actively intervenes in the elevator system. It is purely a
position sensor.
• The scope of the measuring system is not to measure lengths. Lengths vary in particular
because of the temperature and other influencing factors.
3.3.3 TÜV Certification
The following certificate is available for the product described in this manual:
• Certificate of TÜV Austria Services GmbH
Safety characteristics
EC type examination certificate
Classification
PFHd value
Service life
Relevant standard
The certificate is available for download on Kübler's homepage (www.kuebler.com).
3.4 Technical Data
NOTICE
Operation Manual R60073.0009 - 03
TÜV-A-AT-1-19-0599-EUES
SIL 3
<1,0 x10⁻⁸
20 a
EN 81-20:2014
EN 81-50:2014
Technical data
Refer to the data sheets of the corresponding product versions for all
technical data as well as mechanical and electrical characteristics.
For special versions, see the corresponding product offer drawings or
customer drawings.
3 Product Description