DIP
FUNCTION
DEAD MAN
1
function
2
CLOCK Function
3
Start Command
Automatic
4
Closure
Start when
5
Opening
Inversion mode
6
(START1)
7
Pre-flashing
8
Photocell
9
Test Photocell
Type of Safety
10
Device
11
Safety Device
Test Safety
12
Device
SETTING
DESCRIPTION
ON
Enabled
The user opens and closes maintaining this command active
OFF
Disabled
ON
Enabled
When the START2 input is activated, the shutter opens and automatically closes
only after the input is deactivated
OFF
Disabled
ON
Up-Down
START1 controls opening / START2 controls closure
OFF
Start-Stop
START1 controls opening and closure / START2 is disabled
The rolling shutter is closed automatically after the time set on the PAUSE
ON
Enabled
trimmer
The rolling shutter remains open when the open phase ends. Closure must be
OFF
Disabled
commanded with another START command
ON
Enabled
A START command during opening is ignored
OFF
Disabled
A START command during opening is accepted
ON
Enabled
START during opening causes closure. START during closure causes opening.
OFF
Disabled
Step-Step Operation
ON
Disabled
The blinker turns on when the motor is activated
OFF
Enabled
The blinker turns on for 2 seconds and then the motor is started
Activation of the photocell during opening or closing causes the shutter to stop.
ON
Always active
When the photocell is reset, the shutter will open completely
NOT active
Activation of the photocell during opening is ignored. Activation of the
OFF
during opening
photocell during closing causes the complete reopening of the shutter
The controller performs a functional test on the photocells before starting each
ON
Enabled
open or close operation. If the photocells doe not function correctly, the shutter
will not move and the blinker will blink for about 8 seconds.
OFF
Disabled
WARNING: Correctly connect the TX of the photocell (see page 10).
Conductive
Select this operation if you use conductive rubber safety devices with a nominal
ON
rubber edge
resistance of 8K2
Standard or
Select this option if you use traditional safety devices with a normally closed
OFF
optical edge
(NC) contact or with an optical safety device
Activation of the safety device during opening or closing causes the shutter to
ON
Always active
stop. Automatic closure is cancelled
Activation of the safety device during opening is ignored. Activation of the
NOT active
OFF
safety device during closing causes the complete reopening of the shutter.
during opening
Automatic closure is cancelled
The controller performs a functional test of the safety devices before each open
ON
Enabled
or close start. If the safety devices do not function correctly, the shutter will not
move and the blinker will blink for about 8 seconds.
Do NOT enable the test function if you use conductive rubber safety
OFF
Disabled
devices or traditional safety devices that are not equipped with a special
controller for their operation.