V2 EASY2 230V Manual Del Usuario página 11

Cuadro de maniobras analógico para toldos y puertas basculantes
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
DESCRIPTION OF THE CONTROL UNIT
• 230V - 50Hz or 120V - 60Hz power supplies, depending on the
model, for 1 x 700 W max. single phase motor.
• 2 inputs for key selector switch or button activation.
• Input for safety photocell.
• Input for safety edge, capable of handling standard edges with
switch normally closed, optical edges and conductive rubber
edges with nominal resistance of 8.2 kOhms.
• Output for blinking light, 120/230V - 40W
• Pre-opening safety device testing.
• Dip-switch programmable operational logic.
• Adjustment of the operation time by means of a trimmer.
• Quick plug-in connector for inserting a MR series receiver.
• LED monitoring of inputs.
• Courtesy light output.
• IP55 casing.
TECHNICAL SPECIFICATIONS
230V models
Power supply
230 V / 50 Hz
Max motor load
700 W
Max accessories load
3 W
24V
Working temperature
-20 ÷ +60 °C
Protection fuse
F1 = 5A delayed
Dimensions
170 x 185 x 70 mm
Weight
800 g
Protection
IP55
ELECTRICAL CONNECTION TABLE
L1
L2
L3
L4
L5
L6
L7
L8
L9 - L10
L10 - L11 Power supply for functional test TX photocell
120V models
120V / 60Hz
700 W
C1
3 W
C2
-20 ÷ +60 °C
C3
F1 = 8A delayed
D1 - D2
D3 - D4
N
L
J1
ADJUSTMENT OF OPERATING TIMES
The operating times can be adjusted using two trimmers on the
controller:
WORK:
m
shutter in standby
PAUSE:
- 9 -
Antenna
Antenna shield
START1 - Activation input 1 for connection to
traditional devices with NO contacts (open/close)
START2 - Activation input 2 for connection to
traditional devices with NO contacts (close/timer)
STOP command. N.C. switch
Photocell. N.C. switch
Edge. Switch N.C. or resistive rubber edge
Commands common (-) line
Power output 24 Vac for RX photocell and
accessories
Motor open
Motor common
Motor close
Courtesy light timer activation switch
230V - 40W / 120V - 40W blinker
230V / 120V power supply - neutral
230V / 120V power supply - phase
NOT USED
Operating time for the motor (2 to 120 seconds)
WARNING: The times must be adjusted with the
Pause time that precedes automatic closure
(2 to 180 seconds)
loading

Este manual también es adecuado para:

Easy2 120v