3. Standard Function (Dip 1 OFF / DIP 2 OFF)
The following options are available:
Up-Down Operation (Dip 3 ON)
START1 controls opening (open-stop-open-stop)
START2 controls closure (close–stop-close-stop)
Start-Stop Operation (Dip 3 OFF)
START1 controls opening and closure (open-stop-close-stop)
START2 is disabled
Automatic Closure (Dip 4 ON)
Enable closing at the end of the pause time
Condominium Operation (Dip 5 ON)
Open commands are ignored if the shutter is already opening
Inversion mode (Dip 6 ON)
If Start-Stop operation is enabled, START1 changes the direction
of the motion during opening and closing instead of stopping the
shutter.
Dip1 OFF
DEAD MAN function disabled
Dip2 OFF
Clock Function disabled
Individual Controls: START1 opens, START2 closes
ON
(up-down)
Dip3
Unified Controls: START1 opens and closes (start-
OFF
stop)
ON
Automatic Closure Enabled
Dip4
OFF
Automatic Closure Disabled
START1 ignored when opening (Condominium
ON
Logic)
Dip5
OFF
START1 accepted when opening
"Direction Change"
ON
Logic
Dip6
OFF
Step-Step Logic
Connect the wires of the device that controls the START1 input
between terminals L3 and L8 on the controller.
Connect the wires of the device that controls the START2 input
between terminals L4 and L8 on the controller
STOP
The STOP input is intended for devices with the switch normally
closed. The STOP command causes the immediate stop of the
roller shutter.
If the STOP command is given during opening or pause, then
there will be no subsequent automatic re-closure.
Connect the stop input control device cables between terminals
L5 and L8 on the control unit.
Only applied to the
START1 input when in
the Start- Stop mode.
- 13 -
PLUG-IN RECEIVER
The control unit is suitable for plugging-in an MR series receiver
with high sensitivity super-heterodyne architecture.
m
PLEASE NOTE: Disconnect the power to the control
unit before performing the following operations. Pay the
utmost attention to the direction of insertion of plug-in
modules.
The MR receiver module has 4 channels, each with an
associated command on the control unit:
g
• CHANNEL 1
START 1
g
• CHANNEL 2
START 2
g
• CHANNEL 3
STOP
g
• CHANNEL 4
COURTESY LIGHTS
The functional logic for channels 1 and 2 is the same as that set
for the START1 and START2 inputs on the terminal board.
m
PLEASE NOTE: Read the instructions supplied with the
MR receiver thoroughly for details on programming the 4
channels and the operational logic.
EXTERNAL ANTENNA
It is recommended the external antenna be used in order to
guarantee maximum radio capacity.
Connect the antenna hot pole to terminal L1 of the control unit
and the braiding to terminal L2.
FAULT MESSAGES
At the start of each operating cycle, the controller performs an
operational test of the motor drive circuit (Triac).
Furthermore, if enabled by the relative dipswitch, it also performs
a test of the photocell and safety device inputs.
If a fault occurs, the cycle does not start.
The messages are indicated by the warning light:
• Blinks about 4 seconds: Triac fault (or motor disconnected)
• Blinks about 8 seconds: Photocell or safety device fault
PROGRAMMING THE OPERATIONAL
LOGIC
It is possible for the control unit to use several different
operational logic states, by simply moving the dip-switches
located on the card.
The functions associated with each individual dip-switch are listed
below.