Instructions for the air extraction mode
For air extraction mode, a one-way flap should be in-
stalled.
Notes
¡ If a one-way flap is not included with the appli-
ance, one can be ordered from a specialist re-
tailer.
¡ If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.
Checking the units
Check whether the fitted unit is level and has suffi-
1.
cient load-bearing capacity.
The maximum weight of the appliance is approx.
25 kg.
The worktop into which you are fitting the appli-
ance must be able to withstand loads of approx.
60 kg.
Ensure that the stability of the fitted unit is also
2.
guaranteed following cut-out work.
Use suitable substructures to ensure the load-
3.
bearing capacity and stability, particularly in the
case of thin worktops.
Take the appliance weight, including additional
load, into consideration.
Use heat-resistant and moisture-resistant rein-
forcement material.
Ensure that the fitted unit is heat-resistant up to
4.
90 °C.
Do not support any other appliances, e.g. ovens,
5.
refrigerators, dishwashers or washing machines.
Only check that the appliance is level once it has
6.
been installed in the installation opening.
You can freely select the clearance to a top cab-
7.
inet. In doing so, take into consideration the ease
of use and ergonomics when using the plate.
Flush installation
With the flush installation, the appliance and worktop
are on one level. There is no unattractive stepping
between the appliance and the worktop.
You can install the appliance in the following
temperature-resistant and waterproof worktops:
¡ Stone worktops
¡ Plastic worktops, e.g. Corian®
¡ Solid wood worktops
Installation in compressed-wood worktops is not pos-
sible.
Preparing the units
Requirement: The fitted units are heat-resistant up to
90 °C.
Mark the unit cut-out in accordance with the in-
1.
stallation diagram.
→ Fig.
14
Drill four holes with a diameter of 6 mm.
2.
→ Fig.
24
Ensure that the angle of the cut surface to the
3.
worktop is 90°.
→ Fig.
24
Observing the minimum clearances when in-
stalling above a drawer
When removing the overflow container on integ-
1.
rated appliances, take the minimum clearances
into consideration.
→ Fig.
11
Observe the position of the overflow container.
2.
→ Fig.
12
Attaching adhesive tape
Attach the supplied long adhesive tape to the
edge of the worktop.
→ Fig.
25
Preparing the unit for circulating-air mode with the
adapter
Notes
¡ We do not recommend to install on a non-
thermally insulated outer wall or above a cold floor
(µ ≥ 0.5 W/m² °C).
¡ Air outlets must not be directed at other appli-
ances, they should be parted by a separation
panel. If you cannot install any separation panels,
refer to other installation types..
Observe the relevant dimensions when combining
1.
with the adapter for the cut-out in the back wall.
→ Fig.
26
Measure the thickness of the worktop. Transfer
2.
the measurement to the template and draw a line
that corresponds to it.
→ Fig.
27
Cut the template along the marked line for work-
3.
top thickness A, the cut centre line B and the ref-
erence line to the inner air outlet C.
Mark the centre of the cut-out in the worktop as
4.
the centre line on the back panel of the unit.
→ Fig.
28
Align the template to the centre line of the back
5.
panel of the unit and to the lower edge of the
work surface.
Use the template to make the cut-out in the back
6.
panel.
After making the cut-outs, remove any shavings.
7.
Seal the cut surfaces so that they are heat-resist-
8.
ant and waterproof.
→ Fig.
24
Ventilation
In circulating-air mode, establish an air outlet in
1.
the unit's plinth.
Provide a minimum air outlet cross-section of
approx. 400 cm².
Make the outlet opening in the base panel as
large as possible in order to keep draughts and
noise to a minimum.
Make the outlet opening by shortening the
plinth or by using suitable ventilation grilles or a
lamellar plinth.
To guarantee that the appliance works correctly,
2.
ventilate the hob appropriately via an air outlet
with a minimum cross-section of 200 cm² in the
base unit.
Installing an appliance featuring circulating-air mode
with adapter
Attaching the seal to the adapter
Attach the seal to the adapter with max. 5 mm to
the edge.
→ Fig.
29
Attaching the adapter
Clean and degrease the adhesive surface around
1.
the cut-out in the unit's back panel.
Insert the adapter into the outlet opening on the
2.
rear of the hob.
→ Fig.
30
Remove the adhesive tape's protective film from
3.
the adapter.
→ Fig.
31
Inserting the appliance into the worktop cut-out
Ensure that the connection cable is connected to
1.
the appliance.