OPERATING AND MAINTENANCE MANUAL
CENTRIFUGAL ELECTRIC PUMP CH SERIES
The electric surface pumps can be used both for domestic and commercial uses (shops,
light industry and agriculture). Special attention must be paid to the number of machine
starts during normal operation. The instructions to be followed regarding the number of
starts / hour are shown in the following table:
The higher the power of the machine, the lower will be the maximum permissible num-
ber of starts. To regulate the number of pump starts / hour if there are pressurisation
units, adjust the pressure switch settings to increase the differential pressure "ΔP" (see
relative section), or increase the capacity of the tank (add additional ones identical to
the existing one or replace it with a larger one). Pay particular attention to the operation
of the electric pumps with "press control" and / or "pressure-flow regulator" systems: a
minimal and imperceptible leak in the system can cause the electric pump to start-stop
a high number of times and affect its service life. We recommend that you install these
devices together with an autoclave tank, even a small capacity one (0.5 - 1 litres). The
electric pumps referred to will be able to withstand a maximum working pressure (equal
to suction pressure + head pressure with the delivery valve closed) of:
PUMP TYPE
CH
4.
REASONABLY FORESEEABLE MISUSE
• It is strictly forbidden to use the equipment for uses other than those described in the
"Intended use" section and for pumping liquids that:
• contain abrasive substances
• contain solids or fibrous substances
• are flammable or explosive (group I liquids)
www.proindecsa.com / [email protected]
BAR
6
10
METRES
60