Control Panel - Firman H03652 Manual De Instrucciones

Ocultar thumbs Ver también para H03652:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Control Panel

10
NOTE: Total power drawn from all receptacles must not exceed the name plate rating.
Fuel Selector Switch – Use to select and turn
1
on gasoline or LPG fuel source. Fuel (gasoline)
valve is closed when the switch is on "OFF" or
"LPG" positions. Engine switch is on when the
switch is on "GAS" or "LPG" positions.
2
Indicator Light
When the fuel selector switch is turned to the
"GAS" or "LPG" position, the indicator light will
become RED up to 4 minutes(before goes off).
Starting the engine successfully during these
4 minutes will turn the indicator light GREEN.
MUST HAVE SOLID RED INDICATOR LIGHT
TO BE ABLE TO START THE GENERATOR. THE
GENERATOR CANNOT BE STARTED DURING
BATTERY POWER SAVING MODE UNLESS
THE FUEL SELECTOR SWITCH IS TURNED TO
THE "OFF" POSITION AND THEN TURNED
BACK TO THE "GAS" OR "LPG" POSITION.
See Indicator light-Battery power Saving
Mode section for more information.
3
English
1
9
4
5
6
7
8
9
10
Page 12
3
4
2
8
7
6
3-1 Data-Minder(Multi-Meter) – Push the
SELECT button to show the Voltage, Hertz
and running hours.
120V, 20A Duplex – (NEMA 5-20R) 20 Amp
of current may be drawn from this 120 Volt
receptacle.
120V, 30A RV (NEMA TT-30R)
Maximum full load 30 Amp current may be
drawn from this 120 Volt receptacle.
Ground Terminal – Consult an electrician
for local grounding regulations.
120V, 30A Twist-Lock (NEMA L5-30R)
Maximum full load 30 Amp current may be
drawn from this 120 Volt receptacle.
Outlet Cover - Protect the receptacles from
dust and debris.
LPG Hose Connector(Inlet) – Used to connect
LPG hose to generator.
Customer Service: 1-844-FIRMAN1
5
Tabla de contenido

Solución de problemas

loading

Tabla de contenido