Control Panel - Firman W02981 Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Control Panel

16
NOTE:
Total power drawn from all receptacles must not exceed the name plate rating.
1
Engine Switch – Flip the switch to the "ON"(l) position
and pull the recoil starter to start the generator. Turn
to the "OFF"(O) position to turn off the generator.
2
Economy Control Switch
The Economy Control switch can be activated in order to
minimize fuel consumption and noise while operating the
unit during times of reduced electrical output, allowing
the engine speed to idle during periods of non-use. The
engine speed returns to normal when an electrical load is
connected. When the economy switch is off, the engine
runs at normal speed continuously.
3-1 Data-Minder(Multi-Meter) – Push the SELECT
3
button to show the Voltage, Hertz and running hours.
4
120V, 20A Duplex – (NEMA 5-20R) 20 Amp of current
may be drawn from this 120 Volt receptacle.
5
120V, 30A RV (NEMA TT-30R)
30 Amp current may be drawn from this 120 Volt receptacle.
6
Output Ready Indicator Light – Remains "ON"
during normal operating conditions. Shuts "OFF"
when generator is overloaded.
The green AC Power Indicator Light comes on
when the engine starts and generates power.
Overload Indicator Light – This light turns "ON"
7
when the generator is overloaded and will cut
power to the receptacles.
If the engine overload indicator light comes on, the
generator's wattage / amperage capacity has been
exceeded by connected electrical devices or by a
power surge. When this occurs, the green AC Power
English
17
1
2
18
3
Maximum full load
6
7
8
4
Indicator Light(Item 7) will go off. The engine will
continue to run, but the red Engine Overload Indicator
Light will stay on and power will no longer be supplied
to connected electronic devices.
Oil Warning Indicator Light – Check oil level when
8
this light turns "ON". Engine will not run when
indicator is lit.
When the oil falls below the minimum level, the oil
warning indicator light comes on and the engine
stops automatically. The engine will not start until
the proper amount of oil is in the crank case.
DC 5V 2.1A USB Outlet
9
Circuit Breakers – The receptacles are protected by
10
an AC circuit protector. If the generator is overloaded
or an external short circuit occurs, the circuit protector
will trip. If this occurs, disconnect all electrical loads and
try to determine the cause of the problem before
attempting to use the generator again. If overloading
causes the circuit protector to trip, reduce the load.
Note: Continuous tripping of the circuit protector
may cause damage to generator or equipment. The
circuit protector may be reset by pushing the button
of the protector.
DC Circuit Breaker - The circuit protector may be reset
11
by pushing the button of the protector.
Page 08
5
Customer Service: 1-844-FIRMAN1
9
10
11
12
13
14
15
Tabla de contenido

Solución de problemas

loading

Tabla de contenido