Control Panel

12
NOTE: Total power drawn from all receptacles must not exceed the name plate rating.
Fuel Selector Switch – Use to select and turn
1
on gasoline or LPG fuel source. Fuel (gasoline)
valve is closed when the switch is on "OFF" or
"LPG" positions. Engine switch is on when the
switch is on "GAS" or "LPG" positions.
Indicator Light
2
When the fuel selector switch is turned to the
"GAS" or "LPG" position, the indicator light will
become RED up to 4 minutes(before goes off).
Starting the engine successfully during these
4 minutes will turn the indicator light GREEN.
MUST HAVE SOLID RED INDICATOR LIGHT
TO BE ABLE TO START THE GENERATOR. THE
GENERATOR CANNOT BE STARTED DURING
BATTERY POWER SAVING MODE UNLESS
THE FUEL SELECTOR SWITCH IS TURNED TO
THE "OFF" POSITION AND THEN TURNED
BACK TO THE "GAS" OR "LPG" POSITION.
See Indicator light-Battery power Saving
Mode section for more information.
3
Engine Start Switch – Used to start engine
from the starter motor(Electric start model
only). To start engine, press and hold the
switch in the "START"(ll) position, the
engine will crank and attempt to start. When
the engine starts, release the switch to the
"RUN"(l) position.
4
3-1 Data-Minder(Multi-Meter) – Push the
SELECT button to show the Voltage, Hertz
and running hours.
English
2
3
1
5
11
5
6
7
8
Page 11
4
9
8
10
120V, 20A Duplex GFCI (Ground Fault
Circuit Interrupter) – (NEMA 5-20R)
This receptacle is rated so that a total of 20 amps
may be drawn regardless of whether both halves or
just one receptacle is used.
Ground Fault Circuit Interrupter conforms to UL 943,
and NEC requirements. This device protects
you against hazardous electrical shock that may be
caused if your body becomes a path through which
electricity travels to reach ground. This could happen
when you touch an appliance or cord that is " live "
through faulty mechanism, damp or worn insulation, etc.
120V, 30A Twist-Lock (NEMA L5-30R)
Maximum full load 30 Amp current may be
drawn from this 120 Volt receptacle.
120/240V, 30A Twist-Lock – (NEMA L14-30R)
Maximum 30 Amp current maybe drawn from
this 120/240 Volt receptacle.