8.1
Operating conditions
The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in
altitude. Units can only operate while stationary.
8.2
Capacity of the generating set
Before connecting and operating the unit, calculate the electrical power required by the units to be used (in watts)*. To ensure
optimal operation, the total wattage of all equipment used at the same time must be:
-
greater than 60% of the rated load for the unit (risk of insufficient load);
-
less than the rated load for the unit during continuous operation (risk of overload).
If the unit is run under or over its rated load frequently or for long periods of time, it can start to wear very quickly. Damage caused
in this way will not be covered by the warranty.
*
This load is usually indicated in the technical specifications or on the manufacturer's plate for the equipment. Some equipment requires a higher
load when starting. This minimum required power must not exceed the unit's maximum power
8.3
Generating set identification
The identification plate for the unit (example shown below) is affixed inside one of the skirts or on the chassis.
(N)
(B)
Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and
engine serial numbers below.
Unit serial number:
....../.............. - ........................... - .........
1122_EN
(A)
(D)
(E)
(H)
(F)
(I)
(G)
(M)
(c)
.
(A):
Model
(B):
CE/EAC marking
(C):
Guaranteed acoustic
(J)
power level
(K)
(D):
Maximum power
(L)
(E):
Nominal power
(F):
Power factor
Engine brand:
(e.g. Kohler)
........................................
23/240
Section 8. Technical specifications
(G):
Ground
(H):
Current amperage
(I):
Current frequency
(J):
Electrical voltage
(K):
Protection rating
(L):
Reference standard
(M):
Serial number
(N):
UKCA marking
Engine serial number:
(e.g. Kohler (SERIAL NO. 4001200908))
......................................................
2022-08-17
loading

Este manual también es adecuado para:

Perform 3000 c5 rcdPerform 3000 c5 rcd rrbPerform 3000 c5 rrbPerform 4500 c5Perform 4500 c5 rcdPerform 4500 c5 rcd rrb ... Mostrar todo