This LED indicates that one of the protective devices fitted on the power source
has tripped. The protective devices fitted on the power source comprise: thermal
protection; infeed overvoltage or undervoltage; overcurrent protection.
When one of these protective devices is activated the LED illuminates and one of
the following messages is displayed on the digital instrument, depending on the
device that has tripped:
F07 undervoltage/overvoltage.
F06 overcurrent.
F02 thermal protection.
3.2.7 WELDING PARAMETER REGULATION
(Ref. E- Fig. 1 page 3)
This red encoder enables modifications to the parameters in the various menus.
3.2.8 PROGRAMMING KEY (PROG LOAD)
(Ref. E- Fig. 1 page 3)
This key enables power source parameter storage.
3.2.9 MODE KEY (MODE)
This key enables the regulation of the parameters 1 - 2 - 3 - 4 - 5- Fig. 1 page 3) .
3.1.10 SCROLL KEY (STORE)
This key enables the selection of parameters 1 - 2 - 3 - 4 - 5- Fig. 1 page 3) ; when
the MODE key is pressed for parameter setting the LED in position 1 illuminates;
to move onto other parameters simply press the scroll
LEDs illuminate in sequence.
3.2.11 ENABLED PARAMETER LEDS
CONTROL PANEL DESCRIPTION AND FUNCTIONS
These LEDs illuminate according to the variable parameter displayed on the digital
instrument.
Press MODE to enable 1 - 2 - 3 - 4 - 5- Fig. 1 page 3) parameter regulation.
To modify parameters, proceed as follows:
1.
2.
3.
4.
LED 2 illuminates and the last set value is displayed on the digital instrument;
5.
In this section the following welding parameters can be regulated according to the
process selected by means of selector (Ref. A - Fig. 1 page 3)
key; the relative
1.
(GB) 5
Press the MODE key;
LED 1 illuminates and the last set value is displayed on the digital instru-
ment;
Modify the selected parameter by means of the encoder potentiometer (Ref.
E - Fig. 1 page 3) .
Press the scroll key
to move on to parameter 2;
Modify the selected parameter by means of the encoder potentiometer (Ref.
E - Fig. 1 page 3) , and proceed as above.
Set the selector to position 1 (MMA welding) to regulate the arcforce, i.e.:
the characteristics of the power source can be modified during material
deposit on the welding piece. This means that during short circuits a total