DISPLAY MENU
Using the PROG button you can access the following functions in sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
- access the "test" mode;
The status of the security devices TB, FTCI, FTCS
and CSP are always shown on the display.
Memorising the DIP-SWITCH settings and displaying
the rmware version ("03.")
The segments regarding the command status
(LED "ON" = command active) and safety status
(LED "ON" = safety device at rest) light up.
The number of manoeuvres appears on the display.
This number always remains visible until you
change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six gure number.
PRESS
PROG
APL = Setting the limited opening space (gate1):
1 = 1/3 of the distance :
3 = 2/3 of the distance :
PRESS
PROG
SNS = Setting the current sensor.
1 = motor consumption + 2 amps
2 = motor consumption + 3 amps
3 = motor consumption + 3,5 amps
PRESS
PROG
Selecting the type of motor
BL2124 = operator arm
HL2524 = underground operator
CUSTOM = third part motor
PRESS
PROG
Parameters only present in CUSTOM motors
PMT = Motor power setting.
from level 1 (2.5A) to level 8 (6.0A)
PRESS
PROG
SPd= Speed level during deceleration.
1 = minimum speed
2 = medium speed
PRESS
PROG
TB
N.C. N.C. N.C.
FTCS
N.C. N.C. N.C.
FTCI
N.C. N.C. 8.2 K 8.2 K
CSP
N.C. 8.2 K
PRESS
For the values from A to F see the paragraph "contact selection" on page 16
PROG
Deceleration settings
1 (Minimum) 2 - 3 - 4 - 5 (Maximum)
PRESS
PROG
Setting the delay between the gates
1 = minimum gate delay
2 = medium gate delay
PRESS PROG
PRESS PROG
PRESS PROG
2 = half the distance
4 = the entire distance
BLA24 = operator arm
3 = maximum speed
Selecting the type of security contact
0
1
2
3
4
5
6
7
8
N.C.
N.C.
N.C.
N.C.
N.C. 8.2 K 8.2 K
N.C. 8.2 K 8.2 K 8.2 K 8.2 K
N.C. N.C.
N.C.
N.C. 8.2 K 8.2 K
N.C. N.C.
N.C. 8.2 K
N.C. 8.2 K
N.C. 8.2 K
N.C. 8.2 K
3 = maximum gate delay
- set the limited opening distance;
- set the current sensor level;
- selecting the type of motor;
- selecting the security contact
- setting the deceleration time;
- setting the gate delay time.
In the "test" mode (activated when the motor has
stopped) it is possible to check the status of the
command and safety devices.
The warning lights will activate once, each time a
"TA-TC-TAL-TD-TB-FTCI-FTCS-CSP" command is
10 sec
received. To return to the normal mode press the button
again "test" will appear, then wait for 10 seconds.
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 1 to 4).
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 1 to 3).
10 sec
PRESS PROG
Each time the button is pressed
the setting changes.
10 sec
10 sec
10 sec
9
PRESS PROG
Each time the button is
pressed the setting changes
(from 0 ... 9 - A ...F).
10 sec
PRESS PROG
Each time the button is pressed
the number increases (from 1 to 3) .
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 1 to 3) .
10 sec
13
(N.C./8.2 kΩ);
10 sec
PRESS PROG
When the ("TA-TC-TD-TAL-TB- FTCI-FTCS-CSP")
inputs are activated the warning lights will light up.
10 s after the last
modi cation you will
automatically exit the mode
and the selected values will
be saved (eg. 4)
10 s after the last
modi cation you will
automatically exit the mode
and the selected values will
be saved (eg. 3)
10 s after the last modi cation
you will automatically exit the
mode and the selected values
will be saved (eg. underground)
10 s after the last modi cation
you will automatically exit the
mode and the selected values
will be saved (eg. 3)
10 s after the last modi cation
you will automatically exit the
mode and the selected values
will be saved (eg. 2)
10 s after the last
modi cation you will
automatically exit the mode
and the selected values will
be saved (eg. 5)
10 s after the last
modi cation you will
automatically exit the mode
and the selected values will
be saved (eg. 3)
10 s after the last
modi cation you will
automatically exit the mode
and the selected values will
be saved (eg. 3)