PREPARATIONS AND CONNECTIONS
Make sure that the electrode and the extension (if any) are stably inserted in the handpiece housing.
When replacing the electrode and/or extension, make sure that the handpiece is not connected to the
generator or that the generator is turned off (in standby).
Connect the handpiece and foot switch to the high-frequency generator (for models with foot control).
Make sure that the active cable is not directly in contact with the patient's skin and that it is not
tangled.
NB: If the patient is repositioned, always re-check connections.
PRELIMINARY OPERATION CHECK
Manual handpieces: (1) Connect the neutral plate to the patient (2) Connect the handpiece to the
electrosurgical knife (3) Turn the electrosurgical knife on and select the 0 Watt output in the cut and
coagulation function (4) Keep the handpiece away from people and objects and activate the CUT
function (5) Check that the electrosurgical knife signals the activation of the CUT function (6) Repeat
steps 4 and 5 to check the COAG function. Handpieces with foot control: to check their operation,
please refer to the instructions of use of the generator.
USE
Manual handpieces: to activate the cut mode, press the yellow button (CUT); to activate the
coagulation mode, press the blue button (COAG). Handpieces with foot control: to activate the
handpiece, please refer to the instructions of use of the generator.
During the procedure, always select the lowest power level. If the coagulation capacity of the
electrode is below standard, do not increase the high-frequency output before checking:
The proper positioning of the neutral plate;
The proper insertion of cables and of their connectors;
The proper activation of (manual or foot control) operation keys;
That there are no damages to cable insulation;
That the electrode and extension (if any) are not dirty.
European
Conformity
93/42/EEC
2797
Batch code
Sterilized
using
ethylene
oxide
Humidity
limitation
MANCHES PORTE-ÉLECTRODES STÉRILES
FR
À USAGE UNIQUE POUR ÉLECTROCHIRURGIE
MODE D'EMPLOI
MANCHES PORTE-ÉLECTRODES À COMMANDE MANUELLE (SÉRIE F479X)
MANCHES PORTE-ÉLECTRODES PAR PÉDALE (SÉRIE F4390)
INSTRUCTIONS
Produit jetable stérilisé à l'oxyde d'éthylène. Ne pas réutiliser. La réutilisation pourrait entraîner: des
infections croisées dues à la présence de résidus biologiques; l'altération des matériaux; la perte des
propriétés originales du produit.
La stérilité n'est pas garantie si l'emballage a été ouvert et/ou endommagé.
Caution, consult
accompanying
documents
Date of
manufacture
Do not use if
package is
damaged
Temperature
limitation
5 / 40
Consult
instructions
for use
Use by
Do not
contain
natural rubber
latex
Manufacturer
Catalogue
number
Do not reuse
Keep away
from sunlight
Quantity of
pieces
loading