2. General Information
These pumps are to be used for handling septic tank effluent, sewage, and drain (storm) water. X-Series pumps are
CSA Certified to UL778 and CSA C22.2 no. 108, and tested to FM standards for Hazardous (Classified) Locations.
Improper installation, use, or operation of products in a Hazardous (classified) Locations can result in explosion and fire.
All components must be installed in accordance with best practices to minimize the possibility of ignition. All wiring and
electrical installation shall be in accordance with Federal, State, and Local codes by trained professionals.
The pump must be serviced at a qualified hazardous motor enclosure repair facility approved by Liberty Pumps. Any
unauthorized field repairs voids warranty and hazardous location ratings. Contact Liberty Pumps at 1-800-543-2550 to
locate the closest repair facility.
Model
XLSG208M
XLSG202M
XLSG203M
XLSG204M
XLSG205M
XLSGX208M
XLSGX202M
XLSGX203M
XLSGX204M
XLSGX205M
Notes:
X-Series Grinder pumps require the use of a separate control panel. Panels designed for use with the X-Series pumps
are available from Liberty Pumps, and standard models are outlined below.
Single phase pumps require the use of a panel-mounted start circuit consisting of a start and run capacitor and a motor
start relay. These components are available as kits from Liberty Pumps. Please see the table below to identify the
correct kit for the pump being controlled.
All models have a surface temperature (T) class rating of T4; if thermostat is not connected on three phase units, the
temperature rating drops to T3. The float switches must be connected to an intrinsically safe circuit in the control panel.
The minimum water depth for proper motor cooling shall be set at 13".
The use of Non-Liberty panels on 3-phase pumps must have provisions for the thermostat that open the motor
contactors in order to maintain the T4 temperature class. Do not exceed voltage / current combinations for the
thermostat: 16 VDC / 20 Amps, 115 VAC / 22 Amps, 277 VAC / 8 Amps, and 600 VAC / 4 Amps.
Pump Models
XLSG208M
XLSG202M
XLSG203M
XLSG204M
XLSG205M
XLSGX208M
XLSGX202M
XLSGX203M
XLSGX204M
XLSGX205M
HP
Voltage
Phase
2
200
2
230
2
200/230
2
460
2
575
2
200
2
230
2
200/230
2
460
2
575
Liberty Pumps Control Information
Start Capacitor
Run Capacitor
325 µF
275 µF
N/A
N/A
N/A
325 µF
275 µF
N/A
N/A
N/A
©Copyright 2017 Liberty Pumps Inc. All rights reserved.
Full
Locked
Load
Rotor
Amps
Amps
1
18.1
1
15
3
12
3
6.2
3
5
1
20
1
20
3
13.5
3
6.7
3
5.3
Table 1
Cap Kit
65 µF
K001640
50 µF
K001641
N/A
N/A
N/A
N/A
N/A
N/A
65 µF
K001640
50 µF
K001641
N/A
N/A
N/A
N/A
N/A
N/A
Table 2
Thermal
Overload
Temp.
66.5
135° C
64.3
135° C
39.2
120° C
19.6
120° C
16.3
120° C
66.5
135° C
64.3
135° C
39.2
120° C
19.6
120° C
16.3
120° C
Simplex Panel
Duplex Panel
ISS24HS1=3-5
ISD24HS1=3-5
ISS24HS1=3-5
ISD24HS1=3-5
ISS34=3-511-5
ISD34=3-511-5
ISS34=3-191-5
ISD34=3-191-5
ISS54=3-161-5
ISD54=3-161-5
ISS24HS1=3-5
ISD24HS1=3-5
ISS24HS1=3-5
ISD24HS1=3-5
ISS34=3-511-5
ISD34=3-511-5
ISS34=3-191-5
ISD34=3-191-5
ISS54=3-161-5
ISD54=3-161-5
Dis-
charge
1-1/4 "
1-1/4 "
1-1/4 "
1-1/4 "
1-1/4 "
1-1/4 "
1-1/4 "
1-1/4 "
1-1/4 "
1-1/4 "
4