• Ensure that the mains voltage corresponds to the
specifications on the type plate.
• Carry out the electrical installation in accordance
with national regulations.
• Only connect the product to a mains socket with
a residual current device (RCD) with a rated leak-
age current of no more than 30 mA; fuse at least
6 amps.
• Before each use, check the product, cables and
connectors for damage. Defective cables must not
be repaired but replaced with a new ones. Have
damage to your product repaired by a specialist.
• If the mains connection cable for the product is
damaged then it must be replaced by the manufac-
turer or their customer services personnel or by a
similarly qualified person, in order to avoid hazards.
• Do not use the cable to pull the plug out of the out-
let.
• Protect the cable from heat, oil and sharp edges.
• Do not carry or fasten the product by the cable.
• Use only extension cables that are splash-proof
and intended for outdoor use. Always unroll a ca-
ble drum completely before use. Check the cable for
damage.
• Disconnect the mains plug from the socket before
carrying out any work on the product, as well as dur-
ing breaks in work and when not in use.
• Mains connection cables shall not have a smaller
cross-section than rubber hose lines with the desig-
nation H05 RN-F. The cable length must be 10 m.
The conductor core cross-section of the extension
cable must be at least 1.5 mm
Lubricants are used inside the pump which may con-
taminate the liquids flowing out if the product is operat-
ed improperly or damaged.
Warning! This power tool generates an electromagnet-
ic field during operation. This field can impair active or
passive medical implants under certain circumstances.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
6. Residual risks
The machine has been built according to the state-of-
the-art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
.
2
www.scheppach.com
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Before performing setting or maintenance work, un-
plug the mains plug.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with the
operating manual as a whole are observed.
7.
Technical data
Product dimensions
L x W x H
Mains power connection
Rated input
Delivery rate max.
Delivery height max.
Delivery pressure max.
Suction height max.
Pressure connection and
suction connection
Water temperature max.
Protection class
Protection category
Operating mode*
Weight
Subject to technical changes!
Operating mode* S1: Continuous operation at constant
load
Noise
m Warning: Noise can have serious effects on your
health. If the machine noise exceeds 85 dB, please
wear suitable hearing protection.
Noise data
Sound power level L
WA
Sound pressure level L
PA
Uncertainty K
wa/pA
480 x 200 x 300 mm
230 V~ / 50 Hz
1000 W
3800 l/h
36 m
3.6 bar
8 m
G1"
35°C
I
IPX4
S1
8.2 kg
76.6 dB
64.1 dB
2.66 dB