INSTRUCTIONS FOR USE
21.
Repeat step 20 as needed to collect the amount of bone marrow desired.
22.
Once marrow aspiration collection is complete, remove the collection syringe
(unthread) and cap the syringe with a sterile syringe cap.
23.
Attach another syringe to the Cannula and remove the Cannula from the
patient by gently applying outward traction.
IMPORTANT: Do not rock or bend the Cannula during removal.
24.
Discard Cannula, Trocar, Plunger and Adaptor into the proper sharps
container once utilization is complete.
25.
Dress insertion site as appropriate.
Manufactured by: Arteriocyte Medical Systems, Inc., 45 South Street, Hopkinton, MA 01748 USA
DISPOSABLES LIMITED WARRANTY – ARTERIOCYTE MEDICAL SYSTEMS, INC. (OUTSIDE
1
U.S.)
THE FOLLOWING LIMITED WARRANTY APPLIES TO CUSTOMERS OUTSIDE THE UNITED
STATES.
A.
This LIMITED WARRANTY provides assurance for the customer who receives an Arteriocyte
Medical Systems® ("AMS") Magellan
to function to specification, AMS will issue a credit equal to the original Product purchase
price (but not to exceed the value of the replacement Product) against the purchase of any
AMS replacement Product used for that customer. THE WARNINGS CONTAINED IN THE
PRODUCT LABELLING ARE CONSIDERED AN INTEGRAL PART OF THIS LIMITED
WARRANTY. CONTACT YOUR LOCAL AMS REPRESENTATIVE TO OBTAIN
INFORMATION ON HOW TO PROCESS A CLAIM UNDER THIS WARRANTY.
B.
To qualify for the LIMITED WARRANTY, these conditions must be met:
(1) The Product must be used prior to its "Use By" date.
(2) The Product must be returned to AMS within sixty (60) days after use and shall be the
property of AMS.
(3) The Product must not have been altered or subjected to misuse, abuse or accident.
(4) The Product must not have been used more than one time for any customer.
(5) The Product must be used in conformity with the user instructions in the "User Manual"
delivered to the customer together with the Product, of which this LIMITED
WARRANTY is an integral part.
C.
This LIMITED WARRANTY is limited to its express terms. In particular:
(1) In no event shall any replacement credit be granted where there is evidence of
improper handling, improper use or material alteration of the replaced Product.
(2) AMS is not responsible for any incidental or consequential damages based on any
use, defect or failure of the Product, whether the claim is based on warranty, contract,
tort, patent infringement or otherwise.
D.
This LIMITED WARRANTY does not cover those parts that, by their very nature, are likely to
deteriorate or which AMS considers should be periodically replaced consistently with normal
routine or preventative maintenance requirements.
E.
The exclusions and limitations set out above are not intended to, and should not be construed
so as to, contravene mandatory provisions of applicable law. If any part to term of this
LIMITED WARRANTY is held by any court of competent jurisdiction to be illegal,
unenforceable, or in conflict with applicable law, the validity of the remaining portion of the
LIMITED WARRANTY shall not be affected, and all rights and obligations shall be construed
and enforced as if this LIMITED WARRANTY did not contain the particular part or term held
to be invalid.
F.
No representative, agent, dealer, retailer, or intermediary of AMS shall have authorization to
amend the contents of this LIMITED WARRANTY.
G.
The validity, interpretation and performance of the agreement for which this LIMITED
WARRANTY is issued, as well as any disputes relating or connected thereto is controlled by
and construed under the laws of the State of Delaware, USA.
1
This Limited Warranty is provided by the Manufacturer, Arteriocyte Medical
Hopkinton, MA, 01748, USA. It applies only outside of the United States. Areas outside the United States
should contact their local Arteriocyte Medical Systems representative for exact terms of the Limited Warranty
10
English
®
Aspiration Kit ("Product"), that should the Product fail
Systems, Inc., 45 South Street,