Lincoln Electric HARRIS PERFECTFLAME ST Instrucciones De Uso Y Seguridad página 4

Equipo de oxicombustible
Ocultar thumbs Ver también para HARRIS PERFECTFLAME ST:
Idiomas disponibles

Idiomas disponibles

PERFECT FLAME SINGLE TORCH (ST) CONFIGURATION
Part No. 4301946 TECHNICAL INFORMATION/REQUIREMENTS
Input Voltage Range 110/230V AZ 50~60Hz
Input Current
1.5A
Gases Supported Oxygen
Methane (Natural Gas)/Propane/Propylene/ Acetylene/Hydrogen/Butane
Flow Control Technology
Interface Features and Options
Gas Flow Control Adjustment Knobs - SCFH or LPH Readout
Floor Mount Pedestal (P/N 4301947) (27.3lbs.)
Foot Pedal Control (P/N 9104521) (20FT Power Cord) (3.4lbs.)
Gas Pressure/Flow Limits
Gas
Oxygen
Methane
Propane
Acetylene
Hydrogen
Propylene
Butane
Unit Weight
63lbs.
Dimensional Information
Operating Temperature Range
PERFECT
ST
FLAME
FLOOR MOUNT PEDESTAL
4301947
4
Mass Flow Controllers
7" Touch Screen Display - ViziBraze
Inlet (PSIG)
10 – 50
10 – 50
10 – 50
05 – 15
10 – 50
10 – 50
10 – 20
(See Dimensional Drawings for Perfect Flame Single Torch Confi gurations)
32° - 122°F
Oxygen Inlet
One Connection 1/4" NPT(F)/ 9/16"-18(M) RH
Fuel Gas Inlet
One Connection 1/4" NPT(F)/ 9/16"-18(M) LH
Oxygen Outlet
One Connection 1/4" NPT(F)/ 9/16"-18(M) RH
Fuel Outlet
One Connection 1/4" NPT(F)/ 9/16"-18(M) LH
TM
Dash Board
Outlet Flow Limits (SCFH)
2 – 100
2 – 100
2 – 60
2 – 100
2 – 100
2 – 70
2 – 40
36 lbs
loading

Este manual también es adecuado para:

Harris perfectflame mt43019464301945