only with
0 / 4 ... 20 mA
GND
Inductive
load
Fig. 4: Electrical connection with 8-pin M12 plug
6.6.5 Connection with 7-pin M16 plug
Notes
• The maximum current for the digital output is 200 mA (PNP output).
• The digital output is protected against short circuits and overloads.
AVENTICS™ Sentronic 625 | IM502079-014-R01 | English
Control
Digital input (+24 V DC)
+24 V DC
(supply voltage)
0 V DC (supply voltage)
GND
Analog input (set point)
0 ... 10 V
(or 0 / 4 ... 20 mA)
Set point mass
Analog input 2
0 ... 10 V
(or 0 / 4 ... 20 mA)
Analog output (actual value)
max.
0 ... 10 V
500 Ω
(or 0 / 4 ... 20 mA)
Set point mass
Digital output
(pressure switch)
max. 200 mA / 4.8 W
Shield
GND
FE
M12 plug, 8-pin
M12 electrical
connector of the
cable
1
2
7
4
3
5
6
8
Shield
Housing M12 electrical
connector
• For products with 7-pin M16 connector, the analog ground is routed out on a
separate pin.
Procedure
Connect the product according to the pin assignment. See
u
rameters.
7
1
M12 flange plug of the
valve
2
3
250 Ω with
set point 0 / 4 ... 20 mA
250 Ω with
set point 0 / 4 ... 20 mA
Housing M12 flange plug
M4 connection valve housing
6
8
5
4
g 11. Data and pa-
21