The severed plug must be disposed of to avoid a possible
shock hazard and should never be inserted into a mains
socket elsewhere.
Product description and
specifications
Intended use
The battery charger is intended for charging the rechargeable
Würth Li-Ion batteries.
Product features
The numbering of the components shown refers to the diagram
of the charger on the graphics page.
a)
(1)
Battery
(2)
Charging slot
(3)
Red battery charge level indicator
(4)
Green battery charge level indicator
a) Accessories shown or described are not included with
the product as standard. You can find the complete
selection of accessories in our accessories range.
Technical data
Charger
Article number
Battery charging voltage
(automatic voltage detection)
A)
Charging current
Permitted battery temperature
during charging
Charging time at battery ca-
A)
pacity
– 2.0 Ah
– 3.0 Ah
– 4.0 Ah
– 6.0 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01:2014
Protection class
A) Depends on temperature and rechargeable battery type
B) State of charge of the battery is approx. 80%. The battery can be
removed for immediate use.
C) State of charge of the battery is 95 %–100 %.
Operation
The charger can be used either free-standing (for use on a
desktop) or mounted on the wall.
When affixing to the wall: Drill two holes, leaving a clearance
as specified in the image.
To secure it, use round-head screws with a diameter of 5 mm
to max. 6.5 mm.
AL 40-LI
r
5700 139 400
V
10,8–12
A
4.0
Charging process
°
C
0–45
The charging process begins as soon as the mains plug for the
charger is inserted into the mains socket and the battery (1) is
B)
approx. 80 %
/
inserted into the charging slot (2).
C)
battery charged
Thanks to the intelligent charging process, the charge condi-
min
(24)/35
tion of the battery is automatically detected and then charged
up with the optimal charge current depending on battery tem-
min
(36)/50
perature and voltage.
min
(48)/65
In this way, the battery is treated with care and remains per-
min
(72)/95
manently fully charged when it is stored in the charger.
3–6
kg
0,45
Flashing green battery charge level indicator (4)
/ II
Note: The charging process is only possible when the tem-
perature of the battery is within the permitted charging temper-
ature range, see section "Technical data".
Wall mounting
72 mm
Start-up
Note the mains voltage! The voltage of the power
source must match the voltage specified on the rating plate
of the charger. Chargers marked with 230 V can also be
operated with 220 V.
What the display elements mean
The rapid-charging procedure is indicated by
flashing of the green battery charge level in-
dicator (4). The battery can be removed at any
time and used.