GENERGY 5.2KW DC48V Instrucciones De Uso página 70

Sistema solar todo en uno
Idiomas disponibles

Idiomas disponibles

7. Parallel installation guide
7.1 Communication connection
Parallel communication cable (only for 5.2 KW parallel machines)
Connection of 2 inverters in parallel
INVERTER 1: Setting the key 1 of DIP switch to be the bottom position and the key
2,3,4,5 of DIP switch to the top position.
INVERTER 2: Setting the key 2 of DIP switch to be the bottom position and the key
1,3,4,5 of DIP switch to the top position.
Connection of 3 inverters in parallel
INVERTER 1: Setting the key 1 of DIP switch to be the bottom position and the key
2,3,4,5 of DIP switch to the top position.
INVERTER 2: Setting the key 2 of DIP switch to be the bottom position and the key
1,3,4,5 of DIP switch to the top position.
INVERTER 3: Setting the key 1,2 of DIP switch to be the bottom position and the key
3,4,5 of DIP switch to the top position.
Connection of 3 inverters in parallel (another option)
INVERTER 1: Setting the key 1,3 of DIP switch to be the bottom position and the key
2,4,5 of DIP switch to the top position.
INVERTER 2: Setting the key 2,3 of DIP switch to be the bottom position and the key
1,4,5 of DIP switch to the top position.
INVERTER 3: Setting the key 1,2,3 of DIP switch to be the bottom position and the key
4,5 of DIP switch to the top position.
68
loading

Productos relacionados para GENERGY 5.2KW DC48V

Este manual también es adecuado para:

2/3kw dc24v