This function allows moving the operator to verify
the physical limits to locate the magnetic reeds.
The operator moves to one direction meanwhile the
Moving the operator
button (+) is pressed and to the other direction when
it is the button (-) pressed.
It is possible to check on the display if the reeds were
added.
When enabled, this function obstructs the opening
of the gate manually through human strength; when
manually forced to open, the operator automatically
Anti wind
applies the closing movement.
Enabled: Does not allow opening the gate manually
by using force.
Disabled: Allows opening the gate manually.
Pedestrian opening function provides the opening
percentage of the gate, this function is factory set
Pedestrian opening
to 30% and it can be changed from 10% to 90% of
the travel.
It is possible to choose which recorded transmitter
button will send a command to open the percent-
TX pedestrian button
age of the travel chosen in the pedestrian opening
function.
It is possible to determine which terminal of the
Triflex Full Range board will receive the Pedestrian
Pedestrian terminal
Button command, by selecting BOT (Opening and
Closing command) or ABR (Only Opening command).
It is possible to configure one more opening com-
Only opening pushbutton
mand to applying one more access controller.
Language for the Display printing:
-Portuguese
Language
-English
-Spanish
-French
5 – ERASE THE RECOGNIZED GATE TRAVEL
PIn order to erase the acquired travel, simply press both buttons (+) and (-) at the same
time and keep them pressed and await the counting shown on the display, the same may
be done on the PROG, at the end of this process the SN LED of the board will remain lit.
6 – APPLY FACTORY DEFAULTS
In order to return the factory settings to all functions, simply press both buttons (+) and
(-) and hold them pressed and await the counting shown on the display to erase the
travel, keep it pressed until the standard values application counting starts, wait it reach
zero seconds (0s) and then the settings will be factory default, the same may be done on
the PROG, at the end of this process, the SN LED of the board will quickly blink.
22
7 – ANTI-CRUSHING SYSTEM
The anti-crushing feature allows the operator to detect the presence of obstacles in the
gate path. In the normal operating cycle, if an obstacle is detected, the system will take
the following actions:
a) When closing: the gate will be activated in the opening direction.
b) When opening: the engine will shut down and wait for some command to start the
closing.
When recognizing the travel, the anti-crushing feature only has the function of recog-
nizing the opening and closing limits, ie the point of the path where an obstacle was
detected will be interpreted as a limit switch.
WARNING: This anti-crushing system is not enough to avoid accidents with people and
animals; however, it is mandatory the use of photocells in the operators.
8 – ENCODER OPERATION TEST
It is possible to test the encoder of the operator by connecting it to the board and
checking if the "ECA" and "ECB" LEDs are flashing when the operator is moved. Each LED
corresponds to a sensor, for example, the "ECA" LED corresponds to the sensor A, inside
the gear motor.
9 – EVENTS AND FAILURES INDICATIONS
9.1 - MICROCONTROLLER OPERATION INDICATION
The main function of the "SN" LED is to indicate that the controller board is operating. It
flashes with a fixed frequency of ~ 1 Hz.
9.2 - MOTOR OVER CURRENT OR SHORT CIRCUIT INDICATION
The "SN" LED flashes rapidly (in a 0.1- second interval) to warn that the power stage has
tripped due to overcurrent or short circuit in the motor. The board may operate normally
after 10s of the occurrence of the overload.
9.3 - EEPROM FAULT INDICATION
The "SN" LED flashes twice when Memory is not present.
9.4 - EEPROM WITH INVALID DATA INDICATION
The "SN" LED flashes three times when Memory is present, but it has a content that the
microcontroller does not identify as a Valid Transmitter Code.
9.5 - OPEN LIMIT SWITCH INDICATION
The "FC" LED flashes when the gate reaches an open limit switch.
9.6 - CLOSED LIMIT SWITCH INDICATION
The "FC" LED is lit when the gate reaches a closed limit switch.
9.7 - LOAD IN THE CAPACITORS INDICATION
The "BUS" LED indicates that there is load on the power stage capacitors.
WARNING: The power region (capacitor region) of the board must not be touched while
this LED is lit even after the inverter is disconnected from the electricity grid!
9.8 - COMMAND INDICATION
The "CMD" LED on indicates that the board is receiving some command from the digital
inputs, such as ABR, FEC, BOT or FOT.