automatically reverse the movement direction to close; let it reach the closing physical
stop or activate REEDF.
The operator can work only with either ENCODER or ENCODER + REED but it cannot
work only with a REED. During the closing travel recognition only the obstruction of
the external entrapment protection device can reverse the gate movement direction.
The gate is now ready to operate.
3.2 – GATE OPERATION AFTER A POWER CYCLE (TRAVEL RECOGNIZED)
After the previous operation, the gate does not need to recognize the travel again. The
gate simply closes slowly after a command, until it reaches the closing physical stop. The
motor will turn off and the operator is ready to use again. If the photocell is obstructed or
the board receives a command during this first closing, the gate movement direction will
be reversed and, in this case, when the gate is fully opened the operator is ready to use.
NOTE: On Hybrid Mode, or REED + ENCODER, if the gate is in one of the REEDs, the gate
will move with its total speed, without needing the recognition of the travel.
To operate the gate, it is important to install opening and closing physical stops.
4 – JUMPER PARAMETERS PROGRAMMING
4.1 – PROGRAMMING BY THE BUILT-IN DISPLAY
The board has a built-in display that allows programming its parameter similarly to PPA
PROG, the buttons (+) and (-) are to switch the function and the button (F) is for the set-
up menu and it switches the function, as it follows:
18
NOTE:
WARNING:
4.2 – CONTROL DASHBOARD
The built-in display allows observing some important information to functioning and
operating diagnosis, for instance, activated terminals, travel, current speed, number of
cycles and others.
As it follows:
4.3 – PROGRAMMING FUNCTION TABLE
This table is the same for the PROG or built-in display, however when the PROG is activat-
ed, the built-in display is inactivated.
Function
RF Code: Fixed / Rolling
Protocol of reception of RF, Fixed or Rolling
Record or delete function of Transmitters (TX)
1- Record: In this function, the board is ready to re-
cord or delete the transmitters (TX). To record a TX,
press the desired transmitter button, note that the
text "Receiving Signal" shows up, and then press the
button (+) to record. Note that "TX registered" shows
up when it receives a signal already recorded in the
Record TX
board.
2- Delete: To delete the RF transmitters recorded in
the memory, press the Triflex button (-) and (+) or
PROG at the same time for 10s, note theta the text
"Delete TX" shows up and after the 10s the recorded
transmitters will be deleted, and the memory will be
empty.
Time for automatic closing up to two hundred forty
Semi-automatic function /
seconds (240s), when the zero value is selected, the
automatic mode pause time
operator becomes semi-automatic.
Increase or reduce the distance in which the operator
Closing end of travel zone
starts to slow down when closing.
Increase or reduce the distance in which the operator
Opening end of travel zone
starts to slow down when opening.
Adjust the opening and closing speed of the gate.
Opening speed
Note: the adjustment is from 60Hz to 200Hz.
Description