General Safety; General Outline; Technical Data - BFT NETTUNO B Instrucciones De Uso Y De Instalacion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
ENGLISh
Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance.
This product is supplied with an "Instruction Manual" which should be read
carefully as it provides important information about safety, installation, op-
eration and maintenance.
This product complies with recognised technical standards and safety regula-
tions. We declare that it is in conformity with the following European Directives:
89/336/EEC, 73/23/EEC, 98/37/EEC and subsequent amendments.

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
WARNING! Installation must be carried out using the safety devices
and controls prescribed by the EN 12978 Standard.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences result-
ing from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing clos-
ing structures (door, gates etc.), as well as from any deformation which
might occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation opera-
tion area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.

2) GENERAL OUTLINE

The NETTUNO B control panel is supplied by the manufacturer with standard
setting. Any alteration must be set by means of the incorporated display
programmer or by means of
Universal palmtop
unit completely supports the EELINK protocol.
12 - NETTUNO B - Ver. 05
INSTALLATION MANUAL
Its main characteristics are:
-
-
-
-
The board is provided with a terminal board which can be pulled out for
easier maintenance or replacement.
The NETTUNO B control board manages the innovative FAST NET wiring
system.
The FAST NET system allows to connect all the accessories necessary for
the automation of a gate with only 2 ducts. All accessories are connected
in parallel on the same non-polarised telephone-type paired wire through
which the current necessary for powering both the devices and the infor-
mation communication is transmitted. After setting the correct configuration
(paragraph 6.7) each device connected to the FAST NET net is recognized
and identified by giving it an address. If the number of devices connected
to the FAST NET net changes (by adding or eliminating some of them) the
configuration procedure (paragraph 6.7) should be repeated. Up to 16 FAST
NET devices can be connected to the NETTUNO B control board. To connect
a large number of devices more easily, it is possible to connect some of them
between the terminals 13-14 and some others between the terminals 15-16
provided that no more than 16 devices max. are connected. The devices are
subdivided into categories and a maximum number of devices that can be
connected for each category is envisaged (Table 1) but limited to a total of
16 max. that should never be exceeded. Some devices can take 2 addresses
(as if they were 2) and therefore it is recommended to check the number of
addresses occupied by each device on table 2.
Table 1
Table 2
Out of the programming menu, a START command can be given by pressing
the "+" and "OK" keys simultaneously.
ChECK
The NETTUNO B panel carries out a control (check) on the starting relays
and safety devices (photocells etc.) before carrying out each opening and
closing cycle.
In case of malfunction, check the devices connected for regular operation
and check the wiring.

3) TEChNICAL DATA

Power supply: ...............................................................230V~±10% 50Hz*
Mains/low voltage insulation: ....................................... > 2MOhm 500V
Working temperature: ..................................................... from -10 to +55°C
Dielectric strength:.... ....................mains/low voltage 3750V~ for 1 minute
Motor output current: ................................................................2A+2A max
Motor relay commutation current: ......................................................... 10A
Maximum motor power: ........................................................ 48W (24V
Supply to accessories: .......................FAST NET (500mA max absorption)
Gate-open warning light:................................. N.O. contact (24V~/1A max)
programmer. The Control
Dimensions: ...............................................................................see figure 1
Control of two low-voltage motors up to 40W power
Electronic torque setting with obstacle detection
Limit-switch control inputs
FAST NET connection
Device Category
Radio receivers
Blinkers
Control push-buttons
Push-button panel with double
push-button and warning light
Numeric keyboard
Device
FL NET TX - Photocell transimitter FL NET
FL NET RX - Photocell receicer FL NET
NET LAMP - Blinker only
NET LAMP - Blinker with integrated radio receiver
SC NET - START only key selector
SC NET - START + PED key selector
SW NET - START + PED button interface
SW NET - START + OPEN + CLOSE button interface
Max no. of devices that can
be connected
2
4
4 for type (4 start, 4 close...etc)
4
4
N.of Occupied
Addresses
1
1
1
2
1
2
2
3
)
Tabla de contenido
loading

Tabla de contenido