V-TAC SUN-5K-SG04LP3-EU Manual De Instrucciones página 17

Idiomas disponibles

Idiomas disponibles

Safety Hint:
Please use approved DC cable for PV system.
Cable type
Industry generic PV cable
(model: PV1-F)
The steps to assemble the DC connectors are listed as follows:
a) Strip off the DC wire about 7mm, disassemble the connector cap nut (see picture 5.3).
b) Crimping metal terminals with crimping pliers as shown in picture 5.4.
c) Insert the contact pin to the top part of the connector and screw up the cap nut to the top
part of the connector. (as shown in picture 5.5).
Range
4.0~6.0
(12~10AWG)
Chart 3-6
7mm
7mm
Pic 3.3 Disassemble the connector cap nut
Pic 3.4 Crimp the contact pin to the wire
- 15 -
Cross section(mm )
Recommended value
4.0(12AWG)