tau K996MA Guía Para La Instalación página 13

Idiomas disponibles
  • ES

Idiomas disponibles

-
use only M-030000CC50 cable or equivalent.
-
In case of long sections of cables (> 20 m) for N.O./N.C. controls (e.g. OPEN / CLOSE, STOP, PEDE-
STRIAN, etc.), in order to avoid gate malfunctions, it will be necessary to uncouple the various
controls using RELAYS or using our 750T-RELE device.
2. TESTING
When you have completed the connection:
All the green LEDs must be on (each of them corresponds to a Normally Closed input). The go off
only when the controls to which they are associated are operated.
The red DL5 LED must be off (corresponding to the Normally Open OPEN/CLOSE input). It only
comes on when it is activated by the control to which it is associated.
3. TECHNICAL CHARACTERISTICS
Board power supply
Max motor 1 power DC
Max motor 2 power DC
Fast acting fuse for protection of input power supply 13.5V AC (F1 - 5x20)
Fast acting fuse for motors protection (F2 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18V DC (F3 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
4. TERMINAL BOARD CONNECTIONS
Terminals
Function
1 - 2
POWER SUPPLY
3 - 4
MOTOR 1
5 - 6
MOTOR 2
7 - 8
9 - 11
OPEN/CLOSE
10 - 11
SENSITIVE
11 - 12
COURTESY
13 - 14
15 - 16
FLASHING LIGHT
All manuals and user guides at all-guides.com
Description
FS1 - FS2:
transformer housed in the SPIN12Q motor and protected by a
fuse (F 6,3A) on the 230 Vac power supply;
18V DC
motor 1 (M1) supply output 18 Vdc max. 50 W;
18V DC
motor 2 (M2) supply output 18 Vdc max. 50 W;
AERIAL
433,92 MHz built-in RX aerial input; 7 = Signal 8 = Earth;
Input for open/close push button (normally-open contact): for us-
age, see the functions of dip switches 2-4; 9 = Open/close; 11 =
Common;
Stop push button NC (normally closed) contact. After a stoppage,
the system always starts again only after receiving a command
STOP
from the On button or radio transmitter. 10 = Stop; 11 = Com-
mon;
Resistive sensitive edge input (DIP 5=ON); sensitive edge input –
fixed edge (DIP 5=OFF); 11 = Common; 12 = Sensitive edge.
EDGE
If neither the resistive sensitive edge nor the fixed edge are used,
set DIP 5 to OFF and short circuit terminals 11 and 12;
Output for auxiliary courtesy light 18 Vcc max 15 W;
LIGHT
TIVE - 14 = NEGATIVE);
18 Vdc max. 20W output for flashing light supply (15 = POSITIVE -
16 = NEGATIVE), flashing signal supplied by the control unit, rapid
for closing, slow for opening;
board supply input 13.5 Vac – Powered by the toroidal
13
13,5V AC - 50 Hz
50 W - 18V DC
50 W - 18V DC
F 16 A
F 10 A
F 3,15 A
18V DC
18V DC
5V DC
-20 °C ÷ +55 °C
(13 = POSI-
loading