EN
12 ALARMS - ANOMALIES - USEFUL TIPS
Anomalies, causes and possible remedies
Anomaly
Ignition difficulties
Presence of smoke and soot in
the room
The glass dirties very quickly
Condensate build-up
Presence of water in the firebox
The fan (if present) does not
work
Noisy fan (if present)
Little hot air comes out of the
nozzles (if present)
30
Causes
Insufficient combustion air
Non-conforming quality, size and quantity of fuel
Insufficient draught
External air intake not present of with insufficient
cross-sectional size
Fume discharge system clogged or not made
correctly
Loss of smoke from piping
Insufficient draught
Fume discharge system clogged or not made
correctly
External air intake not present of with insufficient
cross-sectional size
Non-conforming quality, size and quantity of fuel
Insufficient draught
Fume discharge system clogged or not made
correctly
Slow combustion and thus excessively low fume
temperature
Fume discharge system and condensate collection
chamber not made correctly
Fume discharge system not made correctly
Lack of power supply in the home
The appliance is not powered
Incorrect power supply connection
Defective control unit
Presence of dust or other objects in the fan
Vibrations in the fan
Worn rotating parts
Ducting pipe not insulated
Ducting pipe with excessively long path and/or too
many bends/branches
Excessively large room in relation to the appliance's
power and capacity of the fan (if present)
Possible solution
Increase the combustion air intake (see "Adjusting
the combustion air").
Use fuel conforming to the indications given under
the chapter "Fuel".
Open the fume adjuster (if present) and the
combustion air primary adjuster.
Clean the fire bed (see "Cleaning the fire bed").
Clean the combustion chamber (see "Cleaning the
combustion chamber").
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the authorised KLOVER Technical
Assistance Centre.
Check the tightness of the fume pipe.
Adjust the fume adjusted (if present).
Clean the fire bed (see "Cleaning the fire bed").
Clean the combustion chamber (see "Cleaning the
combustion chamber").
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the authorised KLOVER Technical
Assistance Centre.
Use fuel conforming to the indications given under
the chapter "Fuel".
Adjust the fume adjusted (if present).
Clean the fire bed (see "Cleaning the fire bed").
Clean the combustion chamber (see "Cleaning the
combustion chamber").
Contact the authorised KLOVER Technical
Assistance Centre.
Increase the combustion air intake (see "Adjusting
the combustion air").
Use smaller-size and more seasoned wood (see
"Fuel").
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the authorised KLOVER Technical
Assistance Centre.
Check the home's electrical system.
Check that the plug is connected to the mains
power and to the appliance and that any switches
of the electrical system are open.
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the authorised KLOVER Technical
Assistance Centre.
Check and clean the fan.
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the authorised KLOVER Technical
Assistance Centre.
Insulate the ducting pipe using suitable materials.
Modify the path and follow the instructions.
Heat fewer rooms or use the appliance together
with other heat generators.
CS.STB.IST-1_EN_Rev.1.0_08-23
MAINTENANCE