st
1
Modality, -STAND-BY OFF- as preset by the factory.
Once the appliance has reached the selected temperature, the modulation starts and it put
itself to power 1 in order to reduce the fuel consumption. When the temperature goes under
the selected value the equipment restore the functioning on setting power. i.e. pow.3)
nd
2
Modality, -STAND-BY ON-.
Once the appliance has reached the selected temperature, the modulation starts, and it put
itself to power 1 in order to reduce the fuel consumption. In case that even at power 1 the
temperature continue to raise, the appliance starts the switch off cycle and the display will
signal " ECO-STOP STAND BY".
MENU 06 (BEEP SOUND)
Within this Menu you can select the modality BEEP (buzzer).
OFF, no sound ON, sound in case of alarm.
MENU 07 (INITIAL LOADING)
With this Menu you can set the continuous fuel load, this operation can only be effected
when the display is evidencing "OFF". This menu is utilized to fill the screw feeder when the
appliance is new or in case of emptying of the pellet container.
MENU 08 (STOVE STATUS)
In this Menu you can find some informations about the working of the (info for technical
staff).
MENU 09 ( correct pellets)
Sometime, changing type of pellet, there are so many types of wood pellet on the market, the
combustion of the appliance can be affected. A clear signal of an inefficient combustion is
given by the quantity of pellets into the burner basket during the normal working phase: too
much or too scarce. It is possible to make some small regulations on the combustion of the
appliance. Under the assumption that during the working phase the burner basket should be
full of pellet from ¼ to half of its capacity, whenever necessary, you can make some
adjustments following the below procedures:
a-
Observe the appliance and verify if the pellet is piling up till to the complete filling
of the basket or if the basket is emptying itself almost till to the extinction of the
fire.
b-
Push P3 to enter MENU.
c-
Scroll the Menu employing P5 and P6 just to arrive to MENU 09
d-
Push again P3 to enter MENU 09.
e-
A PASSWORD is required, employing P1 or P2 run on the number in the upper
part of the screen until you arrive to number 33.
f-
Push again on button P3 to confirm the Access Key and to enter into the modality of
combustion modification
g-
Use buttons P1 and P2 to modify the number shown on the display on the upper
part, as indicated in the below table; to increase the quantity of pellet you must
increase the value, to decrease the quantity of pellet, decrease the value.
ATTENTION! We recommend to modify the value increasing/decreasing by only
one number per time. Verify the working of the appliance for one or two days, after
having cleaned the burner basket, only after this period of verification eventually
make a new regulation.
IT-GB-FR-ES mod. 502-502X-502L-502LX
51/120