Remove the battery from the charging station, by pressing the battery latch button.
Attention! If, when the charger is connected to the power supply, the green LED is on, this indicates a fully charged battery. In this
case, the charger does not start charging.
MAINTENANCE
After each use of the device, turn off the compressor using the power switch and then disconnect both batteries.
Warning! All maintenance works must be carried out with the batteries disconnected from the device.
Then open the drain valve and drain the air from the tank. Take into account that the air coming out of the tank may stir up dust
from the ground on which the compressor will be placed. If necessary, move the compressor to a place where it will be possible
to safely empty the tank from the collected air.
After the air has stopped coming out of the tank, tilt the compressor so that the drain valve is in the lowest position. This will allow
for emptying the tank of water that has accumulated in the tank. Do this thoroughly and after each use of the compressor. Oth-
erwise, the water may lead to tank corrosion and cause its damage Precipitation of water from the air is a natural phenomenon
associated with temperature changes. Therefore, do not neglect to empty the tank from the air.
Clean the air fi lter protecting the air inlet once every 300 hours of operation. Remove the fi lter from the air inlet, open its casing
and clean it with a stream of compressed air at a pressure of not more than 0.3 MPa. After cleaning the fi lter, assemble it and
install it at the air inlet. It is forbidden to use the compressor without an air fi lter. Impurities that will enter the compressor with the
air can lead to its damage.
Clean the other parts of the device with a soft and damp cloth or a compressed air stream with a pressure of not more than 0.3
MPa. You can also clean the ventilation opening with a brush or a brush with soft plastic bristles. Do not use alcohol, solvents,
acids or corrosive agents for cleaning. After cleaning, the compressor is ready for further operation or storage.
TRANSPORT AND STORAGE
Transport the device by grasping the handle or base. When transporting with means of transport, the compressor must be secured
against movement. The device should only be transported and stored when turned off with the batteries disconnected and the air
tank empty. Store the device in closed well-ventilated rooms. During storage and transport, the device should not be exposed to
direct sunlight, heat sources and precipitation. The storage place should protect the device from access by unauthorised persons,
especially children. Do not place anything on the device.