TECE TECEone 9700200 Instrucciones De Uso página 28

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Problem
Water runs/drips
constantly out of the
EN
ceramic
Water temperature
deviates from the
target temperature
Water temperature is
suddenly too high or
too low
Limescale residue on
the ceramics
Toilet lid closes very
slowly
Position of the corner valves:
28
Possible cause
Solution
Check the cartridges are seated correctly
(observe the maximum tightening torque of
10 Nm), check all seals and the connection
of the reinforced hoses. If these measures
are not successful, close the corner valves
(illustration below) or the main valve.
Thermostat cartridge
Adjust the presetting (see assembly instruc-
is defective or incor-
tions on commissioning). Clean or decalcify
rectly adjusted
the cartridges.
Corner valve(s) not
Check if the valves are fully open.
opened properly
Temperature cart-
Call the fitter.
ridge is faulty
Clean the ceramics with a ceramic or porce-
lain cleaner.
This is not a defect. The soft-close and soft-opening functions are
factory-installed in the hinges of the seat and cover unit. Only a little
force is needed to close the lid. It then closes slowly by itself.