Vimar ELVOX EBR1 Manual Para El Conexionado Y El Uso página 20

Barrera 230 v para barras de 3/4 m
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
FRAGMA
to the OPEN1 button or instead of the OPEN1
button. When the control board receives this
command, the boom arm will open and by
keeping this contact closed for all the time of
the boom arm opening, the Clock Function is
automatically activated. In fact, once reached the
open position, the barrier will remain opened and
all of the control board features are blocked. Only
when the OPEN1 button is released, the control
board functions are re-activated and the boom
arm will close immediately.
CLOSE BUTTON (COM - CLOSE)
The CLOSE button performs the close command,
regardless the position of the boom arm.
STEP BY STEP or AUTOMATIC COMMANDS
(COM - K BUTT)
DIP5 - OFF => The K BUTT performs the cyclic
command open-stop-close-stop-
open etc.
DIP5 - ON => The K BUTT performs:
- the open command, if pressed
with the barrier completely closed
- the close command, if pressed
with
the barrier completely
opened
- no effect, if pressed during the
barrier opening
- the boom arm re-open, if pressed
while the barrier is closing
REMOTE CONTROL
DIP4 - OFF => The REMOTE CONTROL performs the cyclic command open-
stop-close-stop-open etc.
DIP4 - ON => The REMOTE CONTROL performs:
- the open command, if pressed with the barrier completely closed
- the close command, if pressed with
opened
OPERATING IN PARK MODE (DIP6 ON)
TO ENTER:
Provided there be a vehicle on the Entry magnetic
loop (see scheme 4), opening can be controlled
by pressing OPEN1, K BUTT or RADIO switch
(OPEN1 performs the boom arm opening only if
the TLC, connected to the Entry Magnetic Loop,
contact is closed).
TO EXIT:
Provided there be a vehicle on the Exit magnetic
loop (see scheme 4), opening can be controlled
by pressing OPEN2, K BUTT, RADIO switch. The
OPEN2 can be connected to the Exit magnetic
loop.
If the DIP8 is turned ON, the OPEN2 will perform
the barrier opening regardless the presence of a
vehicle at the Entry.
If the DIP8 is turned OFF, the OPEN2 will
perform the barrier opening if there is no vehicle
on the magnetic sensor connected to the TLC
input (TLC contact opened).
In both the conditions, TO ENTER and TO EXIT,
from the complete boom arm open position:
If the Automatic Closing is enabled (DIP3
ON), the boom arm will close at the end of the
delay time programmed (see Point D).
If the Automatic Closing is disabled, the
boom arm will remain open until a closing
command is pressed or until the vehicle passes in front of the photocells, giving
an OK CLOSE impulse to the control board (the OK CLOSE command can be
connected to the NO contact of the photocell receiver).
OPEN2 BUTTON (COM - OPEN2) (ONLY PARK MODE)
If the NORMAL MODE is enabled (DIP6 OFF), the OPEN2 command will
be disabled.
If the PARK MODE is enabled (DIP6 ON), the OPEN2 will perform the boom
arm opening depending on the switch DIP8 position.
18
+
K BUTTON
LED
R=2K2
STOP
CLOSE
+
OPEN 1
LSC
LSO
LSSC
LSSO
TIMER
the barrier completely
AERIAL
+
+
BUZZER
K BUTTON
LED
R=2K2
-
STOP
CLOSE
+
OPEN 1
12 Vdc max 0,5A for ACCESSORY SUPPLY
12 Vdc max 0,5A for AUTOTEST EDGE
AERIAL
+
COAX
BUZZER
-
_
_
12 Vdc max 0,5A for ACCESSORY SUPPLY
+
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is closing
AUTOMATIC CLOSING (DIP3 ON)
The Automatic Closing from the complete open position can be enabled turning
ON the DIP3. The maximum time that can be programmed is 5 minutes (see
the Point D).
COAX
_
+
_
+
If DIP8 is turned ON and PARK MODE is enabled, OPEN2 will perform the
boom arm opening regardless the state of the TLC input.
If DIP8 is turned OFF and PARK MODE is enabled, OPEN2 will perform the
boom arm opening only if the TLC contact is OPEN (no vehicle at the Entry, see
scheme 4).
OKCLOSE INPUT (COM - OKCLOSE) (ONLY PARK MODE)
If the NORMAL MODE is enabled (DIP6 OFF), the OKCLOSE command will
be disabled.
If the PARK MODE is enabled (DIP6 ON), the OKCLOSE will perform the
ENTRY
NC
NO
COM
S
S
D-
D-
D
+
D
MAGNETIC LOOP
TO EXIT
MAGNETIC LOOP
TO ENTRY
NC
NO
COM
S
S
D-
D-
D+
D+
MAGNETIC LOOP
TO EXIT
EN