Vimar ELVOX EBR1 Manual Para El Conexionado Y El Uso página 19

Barrera 230 v para barras de 3/4 m
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
FRAGMA
RELAY AND MOTOR COMMAND
K1 => Opening direction command
K2 => Closure direction command
Q4 => TRIAC - Opening and Closing motor command
Q5 => Blinker command
B
- SETTINGS
DIP 1 (ON) MOTOR ROTATION DIRECTION CHECK (See Point
C)
DIP 2 (ON) PROGRAMMING (See Point D)
DIP 1-2
MEMORIZATION/CANCELLATION
CONTROL CODES (POINT E)
DIP 3 ON - Automatic Closing ENABLED (max 5 min)
OFF - Automatic Closing DISABLED
DIP 4 ON - AUTOMATIC Radio Receiver Command
OFF - STEP BY STEP Radio Receiver Command
DIP 5 ON - AUTOMATIC single pulse command (K BUTT.)
OFF - STEP BY STEP single pulse command (K BUTT.)
DIP 6 ON - Operation in PARK MODE
OFF - Operation in NORMAL MODE
WARNING: The PARK MODE enables or disables some features and
commands:
If NORMAL MODE is enabled, OPEN2 command, OK CLOSE
command and TLC (Traffic Light Control) input, are not enabled.
If PARK MODE is enabled all commands are enabled.
DIP 7 OFF
DIP 8 ON - in PARK MODE the OPEN2 button is always enabled
OFF - in PARK MODE the OPEN2 button works if there is no vehicle
on the magnetic sensor connected to the TLC input (TLC
contact opened).
DIP 9 OFF
DIP 10 ON - after the blackout the boom arm automatically closes
OFF - after the blackout the boom arm remains still on the point it was
when blackout occurred
DIP 11 OFF
DIP 12 OFF
DIP 13 ON - Blinker operation with intermittent power supply
OFF - Blinker operation with fixed power supply
DIP 14 DIP 15
DIP16 STANDARD BARRIER
OFF
OFF
OFF
FRAGMA 4A code EBR1
OFF
OFF
ON
FRAGMA 4A code EBR1
LOW SPEED REGULATOR
Slow-speed regulations are carried out by turning the Trimmer LOW SPEED,
it permits to vary the speed of the motor in approaching to the closing position
(turning clockwise to increase the motor speed). This kind of regulation is not
available in approaching to the opening position.
The starting of slowing down is controlled automatically by the limit switches at
approximately 30° before reaching the complete opening and closing position.
LED WARNING
DL1 - Programming activated (red)
DL2 - Stop contact (red)
DL3 - Barrier opening (green)
DL4 - Barrier closing (red)
DL5 - Photocells contact (red)
DL6 - Safety strip contact (red)
DL7 - Closing limit switch contact (red)
DL8 - Opening limit switch contact (red)
DL9 - radio code program (green)
C
- CALIBRATING LOW SPEED MOTOR
This check is meant to facilitate the installer during the start-up of the system
or for any other future controls:
1 - Turn DIP1 to ON, the red led DL1 starts blinking
2 - Press the PROG button and hold it (movement is now performed in "man
present" mode, open-stop-close-stop-open etc.).
If the GREEN led DL3 is on, the boom arm opens. If the RED led DL3 is
on, the boom arm closes.
3 - Carry out the slow-down speed calibration:
- Turn the LOW SPEED trimmer to minimum
- Press and hold the PROG button pressed
- Check whether the low speed has been enabled once LSSC and LSSO
EN
4 - Turn DIP1 to OFF, the red LED DL1 turns off.
During Point C procedure the safety-strip and photocells are not enabled.
D
1 - Close the barrier completely.
OF
RADIO
2 - Turn the DIP 2 to ON, the red led DL1 starts blinking.
3 - Press the PROG button, the boom arm opens.
4 - Once opening has been completed, the boom arm stops. The gap of time
5 - Press the PROG button, the boom arm closes and the Automatic Closing
6 - The red LED DL1 turns off.
7 - Turn DIP2 to OFF.
During Point D procedure, the safety devices (photocells and safety
strip) are active.
E
Programming can be done only when the barrier is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON.
2 - The red LED DL1 flashes ON every 1 sec. and OFF for 10 seconds.
3 - Press the remote control button (usually channel A) within the allotted 10
4 - The programming time for codes is automatically renewed in order to
5 - To finish programming, wait 10 seconds, or press the PROG button briefly.
6 - Reset DIP 1 to OFF and DIP 2 to OFF.
7 - End of procedure.
CANCELLATION OF ALL RADIO CODES
Cancellations can only be performed when barrier is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The red LED DL1 flashes ON every 1 second and OFF for 10 seconds.
3 - Press and hold the PROG button for 5 seconds. Memory cancellation is
4 - The red LED DL1 remains active and you can add new codes as shown
with a 3m boom arm code EBRA.380
with a 4m boom arm code EBRA.480
5 - Reset DIP 1 to OFF and DIP 2 to OFF.
6 - End of procedure.
INDICATOR MEMORY FULL OF RADIO CODES
Indication only when barrier is stationary.
1 - Set DIP 1 to ON and then DIP 2 to ON.
2 - The green LED DL9 flashes 6 times when the memory is full (40 codes).
3 - LED DL1 will then remain active for 10 seconds enabling possible
4 - Reset DIP 1 to OFF and DIP 2 to OFF.
5 - End of procedure.
FUNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE
(DIP6 OFF)
OPEN1 BUTTON (COM - OPEN1)
The OPEN1 button performs the open command, regardless the position of the
boom arm. If the OPEN1 button is pressed during the closing, the boom arm stops
and will reverse the movement in opening. In PARK MODE (DIP6 ON), if there is
a vehicle at the entry (see scheme 4) and the TLC contact is closed, the OPEN1
command opens the barrier. Otherwise, if the TLC contact is open the OPEN1
command is disabled.
CLOCK FUNCTION
The Clock Function permits to keep the boom arm opened even if, for example,
the Automatic Closing is enabled (DIP3 ON) or somebody commands the barrier
closing. It is useful during rush hour, when traffic is heavy and the flow is low (e.g.
entrance/exit of employees, emergencies in residential areas or car parks) and it's
necessary to keep the boom arm opened.
CLOCK FUNCTION APPLICATION
It can be done by connecting a switch and/or a daily/weekly timer either in parallel
limit switches have been reached
- Adjust the LOW SPEED trimmer
WARNING: Make sure the motor is powerful enough to move the bar
during closure. Otherwise increase the value set on the LOW SPEED
trimmer until it reaches the ideal operation condition.
- TIME PROGRAMMING
between now (stop of the motor) and the next pressing of the PROG button
(see step 5 below) will be then stored as waiting time (max 5 minutes) for
Automatic Closing feature.
time is stored (see DIP3 function to enable or disable the Automatic Closing
feature).
- RADIO CODE PROGRAMMING (UP TO 40 CODES)
seconds. If the remote is memorized properly LED DL9 (green) blinks.
memorize the next remote control.
The red LED DL1 stops flashing.
indicated by two flashes of green LED DL9.
above.
cancellation of codes.
17
loading