BlueHelix HiTech RRT H
Index
Description
b27
Calibration procedure [AUTO SETUP]
b28
Not implemented
b29
Restore Factory Values
P30
Heating ramp
P31
Heating standby time
P32
Heating Post-Circulation
P33
Pump operation
P34
Pump modulation DeltaT
P35
Modulating pump min. speed
P36
Modulating pump start speed
P37
Modulating pump max. speed
Pump deactivation temperature during Post-Circu-
P38
lation
Pump activation hysteresis temperature during
P39
Post-Circulation
P40
Heating user max. setpoint
P41
Max. output in heating
P42
Anti-Legionella function frequency
P43
Hot water tank hysteresis
P44
Hot water tank preparation flow
P45
DHW standby time
P46
DHW user max. setpoint
P47
DHW pump Post-Circulation
P48
Max. output in DHW
P49
Not implemented
P50
Not implemented
P51
Hot water tank Off Delta
P52
Not implemented
P53
Not implemented
P54
System pre-circulation time
P55
System filling mode
P56
Minimum system pressure limit value
P57
System nominal pressure value
P58
Maximum system pressure limit value
P59
Circulating pump deactivation with OpenTherm
P60
Frost protection power
P61
Minimum power
P62
Fan minimum speed
EN
Range
5 = Calibration procedure [AUTO SETUP] enabled
All other values = Calibration procedure [AUTO
SETUP] disabled
(See "Calibration procedure [AUTO SETUP]" on
page 314)
--
See *** '* Restore Factory Values' on page 318 ***. 0
10÷80
(ex. 10=20°C/min, 20=12°C/min, 40=6°C/min,
80=3°C/min)
0-10 minutes
0 ÷ 255
(Multiply the value by 10. Example 15 x 10 = 150
seconds)
0 = Continuous pump (active only in winter mode)
1 = Modulating pump
0 ÷ 40°C
30 ÷ 100%
90 ÷ 100%
90 ÷ 100%
0 ÷ 100°C
0 ÷ 100°C
20 ÷ 90°C
0 ÷ 100%
0 = OFF
1÷7 = Days
0 ÷ 80°C
0 ÷ 100°C
30 ÷ 255 seconds
40 ÷ 70°C
0 ÷ 255 seconds
0 ÷ 100%
--
--
0 ÷ 20°C
--
--
0 ÷ 60 seconds
0 = Disabled
1 = Automatic
0-8 bar/10 (Only for boilers with water pressure
sensor)
5-20 bar/10 (Only for boilers with water pressure
sensor)
25-35 bar/10 (Only for boilers with water pressure
sensor)
0 = Circulating pump activated in heating
1 = Circulating pump deactivated in heating with
request from OpenTherm only
0 ÷ 50% (0 = minimum)
0 ÷ 50% (0 = minimum)
DO NOT MODIFY
(The parameters are automatically updated)
cod. 3541V484 - Rev 02 - 01/2024
Default
0
--
40
4
15
1
20
30
90
100
55
25
80
18 kW = 75
28 kW = 100
34 kW = 100
45 kW = 100
0
2
80
120
65
30
18 kW = 75
28 kW = 100
34 kW = 100
45 kW = 100
--
--
10
5
10
30
0
4
7
28
0
0
0
G20/G230:
18 kW = 47
28 kW = 47
34 kW = 49
45 kW = 50
G30/G31:
18 kW = 49
28 kW = 49
34 kW = 48
45 kW = 48