System water pressure adjustment
The filling pressure with system cold, read
on the boiler display, must be approx. 1.0
bar. If the system pressure falls below mini-
mum values, the boiler stops and fault F37 is
displayed. Pull out the filling knob (detail 1 -
fig. 26) and turn it counter-clockwise to re-
turn it to the initial value. Always close it af-
terwards.
Once the system pressure is restored, the
boiler will activate the 300-second air vent-
ing cycle, indicated on the display by Fh.
To prevent boiler shutdown, it is advisable to
periodically check the pressure on the dis-
play with system cold (detail 12 - fig. 1). In
case of a pressure below 0.8 bar, it is advis-
able to restore it.
Display
F40
2.3
bar
1.2
bar
0.7
bar
F37
System draining
The drain cock ring nut is located under the
safety valve inside the boiler.
To drain the system, turn the ring nut (ref. 3
- fig. 27) counter-clockwise to open the
cock. Do not use any tools; use hands only.
To drain only the water in the boiler, first
close the shut-off valves between the sys-
tem and boiler before turning the ring nut.
300
Description
High pressure
Pressure slightly high
Optimum pressure
Pressure slightly low
(The indication with the symbol
visible only if parameter b09 is set to
1).
Low pressure
cod. 3541V484 - Rev 02 - 01/2024
BlueHelix HiTech RRT H
fig. 26- Filling knob
Operation
The boiler stops
The boiler works at reduced power
Normal operation
The boiler continues to work.
is
It is advisable to refill the system as soon as possible.
The boiler stops
fig. 27
1
2
3