Mitsubishi Electric Mr.SLIM PKA-A KA7 Serie Manual De Instrucciones página 12

Ocultar thumbs Ver también para Mr.SLIM PKA-A KA7 Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5. Care and Cleaning
Filter information
Reset filter sign?
Cancel
OK
F1
F2
F3
F4
Filter information
Filter sign reset
Main menu:
Fri
83ºF
Room
Cool
Set temp.
Auto
83
ºF
Mode
Temp.
Fan
If two or more indoor units are connected, filter cleaning timing for
each unit may be different, depending on the filter type.
The icon
will appear when the filter on the main unit is due for
cleaning.
When the filter sign is reset, the cumulative operation time of all units
will be reset.
The icon
is scheduled to appear after a certain duration of
operation, based on the premise that the indoor units are installed in a
space with ordinary air quality. Depending on the air quality, the filter
may require more frequent cleaning.
The cumulative time at which filter needs cleaning depends on the
model.
• This indication is not available for wireless remote controller.
► Cleaning the filters
• Clean the filters using a vacuum cleaner. If you do not have a vacuum
cleaner, tap the filters against a solid object to knock off dirt and dust.
• If the filters are especially dirty, wash them in lukewarm water. Take
care to rinse off any detergent thoroughly and allow the filters to dry
completely before putting them back into the unit.
Caution:
• Do not dry the filters in direct sunlight or by using a heat source,
such as an electric heater: this may warp them.
• Do not wash the filters in hot water (above 50°C, 122°F), as this
may warp them.
• Make sure that the air filters are always installed. Operating the
unit without air filters can cause malfunction.
Caution:
• Before you start cleaning, stop operation and turn OFF the power
supply.
• Indoor units are equipped with filters to remove the dust of sucked-
in air. Clean the filters using the methods shown in the following
sketches.
12
Select "OK" with the [F4] button.
A confirmation screen will appear.
Navigating through the screens
• To go back to the Main menu
....................... [MENU] button
• To return to the previous screen
....................... [RETURN] button
When the
is displayed on the
Main display in the Full mode, the
system is centrally controlled and
the filter sign cannot be reset.
► Filter removal
Caution:
• In removing the filter, precautions must be taken to protect your
eyes from dust. Also, if you have to climb up on a stool to do the
job, be careful not to fall.
• When the filter is removed, do not touch the metallic parts inside
the indoor unit, otherwise injury may result.
PKA-A·KA7
A
B
1 Using both hands, pull both the bottom corners of the intake grille
to open the grille, then lift the filter until it clicks at the stop position.
2 Hold the knobs on the filter and pull the filter up, then pull it out
downward.
(Located in two places, on the left and right.)
A Front grille
B Filter
PCA-A·KA7
C
1 Open the intake grille.
2 Hold the knob on the filter then pull the filter up in the direction of
an arrow. To replace the filter after cleaning, be sure to insert the
filter far enough until it fits into the stopper.
A Filter
B Intake Grille
A
B
D
C Knob
D Stopper

Capítulos

Tabla de contenido
loading

Tabla de contenido