O P E R A T I N G I N S T R U C T I O N S | GTB6V
Figure: Alignment
Sensing range
Check the application conditions: Adjust the sensing range and distance to the object
or background and the remission capability of the object according to the correspond‐
ing diagram
[see figure
3] (x = sensing range, y = monitored area between the set
sensing range and background suppression as a % of the sensing range (object remis‐
sion/background remission)). Remission: 6% = black 1, 18% = gray 2, 90% = white 3
(referring to standard white as per DIN 5033).
The minimum distance (= y) for background suppression can be determined from
diagram [
see figure 3
1] as follows:
Example: x = 150 mm, y = 20 => 20% of 150 mm = 30 mm. That is, the background is
suppressed at a distance of > 180 mm from the sensor.
% of sensing range
30
1
25
6%/90%
20
2
15
18%/90%
10
5
0
0
100
200
300
(3.94)
(7.87)
(11.81)
Distance in mm (inch)
Figure 3: GTB6-xx43x
Example:
Sensing range on black, 6%
x = 100 mm, y = (10% of 100 mm) = 10 mm
3
90%/90%
400
500
(15.75)
(19.69)
White back-
ground (90%)
x
y
8021849.1HTG/2022-11-11 | SICK