4.
Turn actuator through 90°.
5.
Align the diaphragm parallel to the sealing bar. In doing this, position the lugs of the diaphragm precisely between the narrow
guide rails of the inner housing. Tip: Diaphragm can be aligned better in "CLOSED" position.
6.
If necessary, move actuator to "OPEN" position. Position indicator is at the top.
7.
Place actuator on valve body and hand-tighten housing nut. The diaphragm is centered.
8.
Tighten housing nut with strap wrench/special tool until...
a gap dimension of 0.5mm to 1mm is reached between the valve body and the housing nut...
•
and the alignment mark on the housing nut is aligned with the friction lock.
•
Note: For valves with built-in stroke limitation, it is recommended to readjust the valve after reassembly.
Pneumatic diaphragm valve DIASTAR