Rational iCombi Pro 6-1/1 Manual Del Usuario página 16

Ocultar thumbs Ver también para iCombi Pro 6-1/1:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
1 | MI_2130: Removal and installation of the gas blower (including gas valve) hot air and steam
Safety instructions
High voltages when connecting to the mains power
Danger to life due to high voltage.
Disconnect from the power supply.
n
Make sure the unit is disconnected from the power.
n
Sharp edges on the housing
Risk of cuts on the housing when working in the unit.
Wear protective gloves.
Do not use leak detection spray when checking gas components for leaks.
The leak detection spray may damage adjacent components.
Revision Log
Changes from previous version of this manual:
In the chapter "Work steps – Installation of the gas hose on floor units",
n
the note "Do not use leak detection spray when checking gas components
for leaks. The leak detection spray may damage adjacent components." has
been added.
Work steps - Removal of the gas blower (including gas valve) hot air and steam
a
The unit is switched off and voltage-free.
a
The electrical compartment is open.
1. Remove all cables from the gas valve/gas blower unit (1) or (2).
16 / 108
DANGER
CAUTION
NOTICE
loading