1 | MI_2130: Removal and installation of the gas blower (including gas valve) hot air and steam
The documents can be called up by the QR code or the link.
Pict. 4: QR code_en
https://portal.rational-online.com/fs4p/media/service/3_dokumenta-
tionen/icombi_pro___icombi_classik/beipack/divers_1/Sicherheitshin-
weise-Gaskomponenten_en.pdf
Enter the installation of the component on the service level ("Component
replacement" tab). This is an integral part of the maintenance history.
The work steps apply to the gas blower/gas valve unit hot air and steam.
Target group
This document is intended for skilled technicians, who have been certified
n
by the manufacturer after attending training and safety instructions.
Installation, inspection, maintenance, and repair work must only be carried
n
out by trained technicians.
It is recommended that only technicians authorised by the manufacturer
n
perform inspection, maintenance and repair work.
The unit may not be used, cleaned, or maintained by children. The unit may
n
not be used for play. This is prohibited even under supervision.
The unit may not be used, cleaned, or maintained by people with limited
n
physical, sensory, or mental capacity or those without the necessary experi-
ence or knowledge, unless such people are supervised by a person who is
responsible for their safety and who has been informed of the hazards of the
unit.
In order to prevent accidents or damage, the manufacturer recommends
n
that technicians attend training and safety instructions.
NOTICE
15 / 108