Nilfisk Gerni 2302A Instrucciones De Manejo página 33

Tabla de contenido
Symptoms
By-pass valve
"hammers" or pressure
gauge oscillates.
Safety valve starts func-
tioning or high pressure
cleaner operates at too
high a pressure.
Nozzle does not tilt.
Turbo Laser leaks.
No detergent added.
Boiler smokes.
The burner cuts out
during operation.
The burner starts and
stops incorrectly with correct
working pressure.
Burner does not light.
High pressure cleaner
does not operate at max.
pressure/pressure oscil-
lates.
The water does not reach
operating temperature.
FAULT FINDING
Cause
Nozzle partly blocked.
Pressure outlet systerm leaks.
Primary nozzle partly blocked.
Pressure nozzle partly blocked.
Turbo Laser dirty.
Turbo Laser filter dirty.
Gaskets defective.
Detergent tank empty.
Detergent filter dirty.
Metering valve closed.
Water in the fuel.
Air in the fuel system.
Thermostat set too low.
No water supply.
No fuel.
Fuel filter dirty.
Water in the fuel.
Fuel tank emty
Insufficient water.
Fuel filter dirty.
Thermostat set too low.
Wrong phase sequence.
Thermostat set too low.
Fuel filter dirty.
Water in the fuel.
Fuel tank emty
Suction side of pump leaks (takes in air).
High pressure nozzle blocked.
The machine needs descaling.
High pressure nozzle worn.
Air in the system.
Operating thermostat set too low.
Fuel filter dirty.
The machine needs descaling.
Corrective action
Remove and clean the nozzle.
Contact service department.
Remove and clean front nozzle.
Remove and clean pressure nozzle.
Disconnect and clean Turbo Laser.
Clean/change the filter (see maintenance).
The leak may seal itself by continued usage.
Change gaskets (Service kit).
Fill up.
Clean detergent filter.
Open.
Empty and clean fuel tank (see maintenance) .
If the fuelsupply has been switched off ( at first time start or
if the fuel hoses have been taken out of the fuel tank) there
will beair in the fuel system when you start the machine.
Turn start/stop button clockwise clockwise to max. tempera
ture. after a few minutes the system has been bled and the
combustiion is back to normal. If the machine is equipped
with a flame control it might be necessary to rest the
start/stop button during air escape.
Check thermostat setting and make correction.
Turn on water.
Fill tank.
Clean fuel filter (see maintenance).
Empty and clean fuel tank (see maintenance).
Add fuel
The water tap fully open.
Clean fuel filter (see maintenance).
Check thermostat setting and reset.
Change phases in the electric plug.
Check thermostat setting and make correction.
Clean fuel filter (see maintenance).
Empty and clean fuel tank (see maintenance).
Add fue.
Check for leaks, tighten hose clamps.
Disconnect nozzle and clean it carefully.
Descale the machine according to maintenance.
Install new nozzle. Note type (see technical data).
Bleed out the cleaner. Open pressure regulating handle,
activate the pistol.
Let the machine run until stable pressure is reached.
Check thermostat setting and make correction.
Clean fuel filter (see maintenance).
Descale the machine according to maintenance.
33
Tabla de contenido
loading

Este manual también es adecuado para:

Gerni 2502aGerni 2702a

Tabla de contenido